Methyl Isobutyl Ketone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Optima-5 MSOV-101SPB-1SPB-5SPB-5
Column length (m) 30.25.30.60.60.
Carrier gas HeliumNitrogenHelium  
Substrate      
Column diameter (mm) 0.250.200.250.320.32
Phase thickness (μm) 0.250.251.01.1.
Tstart (C) 35.40.60.40.40.
Tend (C) 250.240.250.230.230.
Heat rate (K/min) 10.6.5.3.3.
Initial hold (min) 3. 5.5.5.
Final hold (min) 5.  5.5.
I 728.753.721.739.739.
ReferenceGoeminne, Vandendriessche, et al., 2012Zenkevich, Eliseenkov, et al., 2011Frerot, Velluz, et al., 2008Vasta, Ratel, et al., 2007Vasta, Ratel, et al., 2007
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase BP-1HP-5DB-1DB-5OV-101
Column length (m) 50.25.60.30.50.
Carrier gas He HeH2 
Substrate      
Column diameter (mm) 0.220.200.320.320.28
Phase thickness (μm) 0.750.331.01. 
Tstart (C) 50.50.40.40.80.
Tend (C) 200.180.280.220.200.
Heat rate (K/min) 5.5.2.3.2.
Initial hold (min)  3.   
Final hold (min)      
I 723.741.732.735.725.
ReferenceHealth Safety Executive, 2000Jung, Wichmann, et al., 1999Tai and Ho, 1998Moio, Dekimpe, et al., 1993Anker, Jurs, et al., 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase SF-96
Column length (m) 111.
Carrier gas Nitrogen
Substrate  
Column diameter (mm) 0.76
Phase thickness (μm)  
Tstart (C)  
Tend (C) 130.
Heat rate (K/min) 3.
Initial hold (min) 8.
Final hold (min) 40.
I 730.
ReferenceDonetzhuber, Johansson, et al., 1976
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Goeminne, Vandendriessche, et al., 2012
Goeminne, P.C.; Vandendriessche, T.; Van Eldere, J.; Nicolai, B.M.; Hertog, M.L.; Dupont, L.J., Detection of Pseudomonas aeruginosa in sputum headspace through volatile organic compound analysis, Respiratory Res., 2012, 13, 87, 1-9. [all data]

Zenkevich, Eliseenkov, et al., 2011
Zenkevich, I.G.; Eliseenkov, E.V.; Kasatochkin, A.N.; Zhakovskaya, Z.A.; Khoroshko, L.O., Gas chromatographic identification of chlorination products of aliphatic ketones, J. Chromatogr., 2011, 1218, 21, 3291-3299, https://doi.org/10.1016/j.chroma.2010.12.056 . [all data]

Frerot, Velluz, et al., 2008
Frerot, E.; Velluz, A.; Bagnoud, A.; Delort, E., Analysis of the volatile constituents of cooked petai beans (Parkia speciosa) using high-resolution GC/TOF-MS, Flav. Fragr. J., 2008, 23, 6, 434-440, https://doi.org/10.1002/ffj.1902 . [all data]

Vasta, Ratel, et al., 2007
Vasta, V.; Ratel, J.; Engel, E., Mass Spectrometry Analysis of Volatile Compounds in Raw Meat for the Authentication of the Feeding Background of Farm Animals, J. Agric. Food Chem., 2007, 55, 12, 4630-4639, https://doi.org/10.1021/jf063432n . [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Jung, Wichmann, et al., 1999
Jung, A.; Wichmann, K.-H.; Kolb, M., VOC emission of polymeric packaging materials, LaborPraxis, 1999, 23, 9, 20-22. [all data]

Tai and Ho, 1998
Tai, C.-Y.; Ho, C.-T., Influence of glutathione oxidation and pH on thermal formation of Maillard-type volatile compounds, J. Agric. Food Chem., 1998, 46, 6, 2260-2265, https://doi.org/10.1021/jf971111t . [all data]

Moio, Dekimpe, et al., 1993
Moio, L.; Dekimpe, J.; Etievant, P.; Addeo, F., Neutral volatile compounds in the raw milks from different species, J. Dairy Res., 1993, 60, 2, 199-213, https://doi.org/10.1017/S0022029900027515 . [all data]

Anker, Jurs, et al., 1990
Anker, L.S.; Jurs, P.C.; Edwards, P.A., Quantitative structure-retention relationship studies of odor-active aliphatic compounds with oxygen-containing functional groups, Anal. Chem., 1990, 62, 24, 2676-2684, https://doi.org/10.1021/ac00223a006 . [all data]

Donetzhuber, Johansson, et al., 1976
Donetzhuber, A.; Johansson, K.; Sandstroem, C., Gas phase characterization of wood, pulp, and paper, Appl. Polymer Symp., 1976, 28, 889-901. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References