Procaine


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedCapillaryPacked
Active phase SE-30SE-30SE-30SPB-1SE-30
Column length (m) 2.1.1.25.2.
Carrier gas N2N2N2He 
Substrate 1% se-30 on Anachrom ABS(80-100mesh)Inerton N AW (1), NaCl (2), and steel powder (3)Inerton N AW (1), NaCl (2), and steel powder (3) Anakrom ABS
Column diameter (mm)    0.20 
Phase thickness (μm)      
Temperature (C) 220.210.210.250.220.
I 2014.2031.2046.2049.2029.
ReferenceMusumarra, Scarlata, et al., 1987Lenchik, Rudenko, et al., 1986Lenchik, Rudenko, et al., 1986Lora-Tamayo, Rams, et al., 1986Mari, Bertol, et al., 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPacked
Active phase SE-30OV-101OV-101
Column length (m) 2.  
Carrier gas    
Substrate Anakrom ABS  
Column diameter (mm)    
Phase thickness (μm)    
Temperature (C) 260.180.190.
I 2035.1998.2005.
ReferenceMari, Bertol, et al., 1984Delbeke, Debackere, et al., 1981Delbeke, Debackere, et al., 1981
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Musumarra, Scarlata, et al., 1987
Musumarra, G.; Scarlata, G.; Romano, G.; Cappello, G.; Clementi, S.; Giulietti, G., Qualitative organic analysis. Part 2. Identification of drugs by principal components analysis of standardized TLC data in four eluent systems and of retention indices on SE 30, J. Anal. Toxicol., 1987, 11, 4, 154-163, https://doi.org/10.1093/jat/11.4.154 . [all data]

Lenchik, Rudenko, et al., 1986
Lenchik, N.V.; Rudenko, B.A.; Dzhabarov, D.N., Gas chromatographic analysis of nitrogen-containing pharmaceticals using a thermoaerosol detector and non-porous sorbents, Zh. Anal. Khim., 1986, 1438-1443. [all data]

Lora-Tamayo, Rams, et al., 1986
Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 1986, 374, 73-85, https://doi.org/10.1016/S0378-4347(00)83254-5 . [all data]

Mari, Bertol, et al., 1984
Mari, F.; Bertol, E.; Tosti, M., Benzoyltropeine, an unusual substance in street heroin samples, Bull. Narc., 1984, 1, 59-67. [all data]

Delbeke, Debackere, et al., 1981
Delbeke, F.T.; Debackere, M.; Desmet, N., Detection of some local anaesthetics in horse urine and plasma by gas-liquid chromatography, J. Chromatogr., 1981, 206, 3, 594-599, https://doi.org/10.1016/S0021-9673(00)88931-1 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References