Cyclohexene,1-(2-propenyl)-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryApiezon L100.971.Eisen, Orav, et al., 1972Column length: 45. m; Column diameter: 0.25 mm
CapillaryApiezon L120.979.Eisen, Orav, et al., 1972Column length: 45. m; Column diameter: 0.25 mm
CapillarySqualane60.929.2Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillarySqualane80.934.5Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillarySqualane60.929.Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm
CapillarySqualane80.934.Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryPEG 4000100.1154.Rang, Orav, et al., 1988 
CapillaryPEG 400060.1134.Rang, Orav, et al., 1988 
CapillaryPEG 400080.1144.Rang, Orav, et al., 1988 
CapillaryPolyethylene Glycol 4000100.1154.1Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPolyethylene Glycol 400060.1134.2Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPolyethylene Glycol 400080.1144.0Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPEG 4000100.1154.1Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPEG 400060.1134.2Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPEG 400080.1144.Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySqualane929.Chen, 2008Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Eisen, Orav, et al., 1972
Eisen, O.; Orav, A.; Rang, S., Identifizierung von Normal-Alkenen, Cyclopentenen und -Hexenen mittels Kapillar-Gas-Chromatographie. Identification des alcènes, cyclopentènes et -hexènes à l'aide de la chromatogrpahie en phase gazeuse sur colonne capillaire, Chromatographia, 1972, 5, 11, 229-239, https://doi.org/10.1007/BF02270600 . [all data]

Orav and Eisen, 1972
Orav, A.; Eisen, O., The retention indexes for alkenes, alkynes and cyclenes on capillary columns, Izv. Akad. Nauk Est. SSR, Khim. Geol., 1972, 21, 1, 39-47. [all data]

Rang, Orav, et al., 1988
Rang, S.A.; Orav, A.E.; Kuningas, K.R.; Meister, A.E.; Strense, T.V.; Eisen, O.G., Gas-Chromatographic Characteristics of unsaturated hydrocarbons, Academy of Sciences of Estonia SSR, Tallinn, Estonia SSR, 1988, 208. [all data]

Chen, 2008
Chen, H.-F., Quantitative prediction of gas chromatography retention indices with support vector machines, radial basis neutral networks and multiple linear regression, Anal. Chim. Acta, 2008, 609, 1, 24-36, https://doi.org/10.1016/j.aca.2008.01.003 . [all data]


Notes

Go To: Top, Gas Chromatography, References