Propene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedCapillaryCapillaryCapillaryCapillary
Active phase Porapack QCP Sil 5 CBPoraPLOT QOV-1Squalane
Column length (m)  25.10.150. 
Carrier gas  H2H2He 
Substrate      
Column diameter (mm)  0.150.320.50 
Phase thickness (μm)  2.10.  
Temperature (C) 100.20.160.20.50.
I 292.294.300.289.283.3
ReferenceJi, Majors, et al., 1999Do and Raulin, 1992Do and Raulin, 1989Nijs and Jacobs, 1981Schröder, 1980
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedCapillaryPackedPackedPacked
Active phase SqualaneSqualaneSqualaneSqualaneSqualane
Column length (m)  91.415.15.15.
Carrier gas  N2HeHeHe
Substrate   Chromosorb PChromosorb PChromosorb P
Column diameter (mm)  0.250.250.250.25
Phase thickness (μm)      
Temperature (C) 80.40.27.49.67.
I 287.289.287.287.288.
ReferenceChrétien and Dubois, 1977Matukuma, 1969Hively and Hinton, 1968Hively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase SqualaneSqualane
Column length (m) 15.10.
Carrier gas He 
Substrate Chromosorb P 
Column diameter (mm) 0.25 
Phase thickness (μm)   
Temperature (C) 86.26.
I 288.289.
ReferenceHively and Hinton, 1968Zulaïca and Guiochon, 1966
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ji, Majors, et al., 1999
Ji, Z.; Majors, R.E.; Guthrie, E.J., Review. Porous layer open-tubular capillary columns: preparations, applications, and future directions, J. Chromatogr. A, 1999, 842, 1-2, 115-142, https://doi.org/10.1016/S0021-9673(99)00126-0 . [all data]

Do and Raulin, 1992
Do, L.; Raulin, F., Gas chromatography of Titan's atmosphere. III. Analysis of low-molecular-weight hydrocarbons and nitriles with a CP-Sil-5 CB WCOT capillary column, J. Chromatogr., 1992, 591, 1-2, 297-301, https://doi.org/10.1016/0021-9673(92)80247-R . [all data]

Do and Raulin, 1989
Do, L.; Raulin, F., Gas chromatography of Titan's atmosphere. I. Analysis of low-molecular-weight hydrocarbons and nitriles with a PoraPLOT Q porous polymer coated open-tubular capillary column, J. Chromatogr., 1989, 481, 45-54, https://doi.org/10.1016/S0021-9673(01)96751-2 . [all data]

Nijs and Jacobs, 1981
Nijs, H.H.; Jacobs, P.A., On-Line Single Run Analysis of Effluents from a Fischer-Tropsch Reactor, J. Chromatogr. Sci., 1981, 19, 1, 40-45, https://doi.org/10.1093/chromsci/19.1.40 . [all data]

Schröder, 1980
Schröder, I.H., Retention Indices of Hydrocarbons up to C14 for the Stationary Phase Squalane, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1980, 3, 1, 38-44, https://doi.org/10.1002/jhrc.1240030115 . [all data]

Chrétien and Dubois, 1977
Chrétien, J.R.; Dubois, J.E., Topological analysis of gas-liquid chromatographic behavior of alkenes, Anal. Chem., 1977, 49, 6, 747-756, https://doi.org/10.1021/ac50014a021 . [all data]

Matukuma, 1969
Matukuma, A., Retention indices of alkanes through C10 and alkenes through C8 and relation between boiling points and retention data, Gas Chromatogr., Int. Symp. Anal. Instrum. Div Instrum Soc. Amer., 1969, 7, 55-75. [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]

Zulaïca and Guiochon, 1966
Zulaïca, J.; Guiochon, G., Analyse des hauts polymères par chromatographie en phase gazeuse de leurs produits de pyrolyse. II. Application à quelques hydrocarbures macromoléculaires purs, Bull. Soc. Chim. Fr., 1966, 4, 1351-1363. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References