Ethane, 1,2-dichloro-1,1,2,2-tetrafluoro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Condensed phase thermochemistry data

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
ALS - Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
DH - Eugene S. Domalski and Elizabeth D. Hearing

Quantity Value Units Method Reference Comment
Δfliquid-960.2 ± 7.3kJ/molCcrErastov and Kolesov, 1986Correction of Papina and Kolesov, 1982; ALS
Quantity Value Units Method Reference Comment
Δcliquid-589.9 ± 6.8kJ/molCcrErastov and Kolesov, 1986Correction of Papina and Kolesov, 1982; ALS
Quantity Value Units Method Reference Comment
liquid282.0J/mol*KN/AKolesov, Kosarukina, et al., 1981DH

Constant pressure heat capacity of liquid

Cp,liquid (J/mol*K) Temperature (K) Reference Comment
164.0298.15Kolesov, Kosarukina, et al., 1981T = 8 to 300 K.; DH
169.9293.3Perlick, 1937T = -188 to 20°C. Value is unsmoothed experimental datum.; DH
169.9293.3Perlick, 1937, 2T = -188 to 20°C. Value is unsmoothed experimental datum.; DH

IR Spectrum

Go To: Top, Condensed phase thermochemistry data, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compiled by: Coblentz Society, Inc.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director


Mass spectrum (electron ionization)

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
NIST MS number 6721

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryBP-1359.Health Safety Executive, 200050. m/0.22 mm/0.75 μm, He, 5. K/min; Tstart: 50. C; Tend: 200. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySPB-1352.Flanagan, Streete, et al., 199760. m/0.53 mm/5. μm, He; Program: 40C(6min) => 5C/min => 80C => 10C/min => 200C
CapillarySPB-1352.Strete, Ruprah, et al., 199260. m/0.53 mm/5.0 μm, Helium; Program: 40 0C (6 min) 5 0C/min -> 80 0C 10 0C/min -> 200 0C
CapillarySPB-1361.Strete, Ruprah, et al., 199260. m/0.53 mm/5.0 μm, Helium; Program: not specified

References

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Erastov and Kolesov, 1986
Erastov, P.A.; Kolesov, V.P., The energy of combustion of liquid 1,2-dichlorotetrafluoroethane, Thermochim. Acta, 1986, 109, 175-180. [all data]

Papina and Kolesov, 1982
Papina, T.S.; Kolesov, V.P., Standard enthalpy of formation of 1,2-dichlorotetrafluoroethane, Petro. Chem. USSR, 1982, 56, 675-677, In original 1108. [all data]

Kolesov, Kosarukina, et al., 1981
Kolesov, V.P.; Kosarukina, E.A.; Zhogin, D.Yu.; Poloznikova, M.E.; Pentin, Yu.A., Heat capacities, phase transitions, and thermodynamic functions of 1,1,2,2,-tetrafluoro-1,2-dichloroethane and 1,1,3-trifluoro-1,2,2-trichloroethane, J. Chem. Thermodynam., 1981, 13, 115-129. [all data]

Perlick, 1937
Perlick, A., Calorimetric investigations on dichloromethane, difluoromonochloroethane and tetrafluorodichloroethane, Bull. Int. Inst. Refrig., 1937, 18, 1-9. [all data]

Perlick, 1937, 2
Perlick, A., Kalorimetrische Messungen an Schwefeldioxyd, Methylenchlorid, Difluormonochloraethan und Tetrafluordichloraethan, Z. ges. Kalt-Ind., 1937, 44, 201-206. [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Flanagan, Streete, et al., 1997
Flanagan, R.J.; Streete, P.J.; Ramsey, J.D., Volatile Substance Abuse, UNODC Technical Series, No 5, United Nations, Office on Drugs and Crime, Vienna International Centre, PO Box 500, A-1400 Vienna, Austria, 1997, 56, retrieved from http://www.odccp.org/pdf/technicalseries1997-01-011.pdf. [all data]

Strete, Ruprah, et al., 1992
Strete, P.J.; Ruprah, M.; Ramsey, J.D.; Flanagan, R.J., Detection and identification of volatile substances by headspace capillary gas chromatography to aid the diagnosis of acute poisoning, Analyst, 1992, 117, 7, 1111-1127, https://doi.org/10.1039/an9921701111 . [all data]


Notes

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References