Methane, tetraiodo-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas phase thermochemistry data

Go To: Top, Gas phase ion energetics data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein

Quantity Value Units Method Reference Comment
Δfgas64.040kcal/molCmKudchadker and Kudchadker, 1976 

Gas phase ion energetics data

Go To: Top, Gas phase thermochemistry data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
LBLHLM - Sharon G. Lias, John E. Bartmess, Joel F. Liebman, John L. Holmes, Rhoda D. Levin, and W. Gary Mallard
LLK - Sharon G. Lias, Rhoda D. Levin, and Sherif A. Kafafi

Ionization energy determinations

IE (eV) Method Reference Comment
8.95PEJonkers, De Lange, et al., 1982LBLHLM
9.10PEJonkers, De Lange, et al., 1982Vertical value; LBLHLM

Appearance energy determinations

Ion AE (eV) Other Products MethodReferenceComment
I2+11.3 ± 0.1?EIDeCorpo and Franklin, 1971LLK

Gas Chromatography

Go To: Top, Gas phase thermochemistry data, Gas phase ion energetics data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1862.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified

References

Go To: Top, Gas phase thermochemistry data, Gas phase ion energetics data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kudchadker and Kudchadker, 1976
Kudchadker, S.A.; Kudchadker, A.P., Erratum: Ideal gas thermodynamic properties of eight bromo- and iodomethanes, J. Phys. Chem. Ref. Data, 1976, 5, 529-530. [all data]

Jonkers, De Lange, et al., 1982
Jonkers, G.; De Lange, C.A.; Snijders, J.G., Effects of relativity in the He(I) photoelectron spectrum of CI4, Chem. Phys., 1982, 69, 109. [all data]

DeCorpo and Franklin, 1971
DeCorpo, J.J.; Franklin, J.L., Electron affinities of the halogen molecules by dissociative electron attachment, J. Chem. Phys., 1971, 54, 1885. [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]


Notes

Go To: Top, Gas phase thermochemistry data, Gas phase ion energetics data, Gas Chromatography, References