- Formula: C8H20O4Si
- Molecular weight: 208.3275
- IUPAC Standard InChIKey: BOTDANWDWHJENH-UHFFFAOYSA-N
- CAS Registry Number: 78-10-4
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: Silicic acid (H4SiO4), tetraethyl ester; Dynasil A; Ethyl orthosilicate; ES 28 (ester); Silane, tetraethoxy-; Silicon ethoxide; Silicon tetraethoxide; Tetraethoxysilane; Tetraethoxysilicon; Tetraethyl orthosilicate; TEOS; (C2H5O)4Si; Ethyl silicate, ((EtO)4Si); Etylu krzemian; Silicate d'ethyle; Silicate tetraethylique; Silicic acid, tetraethyl ester; Tetraethylsilikat; UN 1292; ES 100; ES 28; NSC 4790; Silikan L
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Condensed phase thermochemistry data
Go To: Top, Gas phase ion energetics data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Eugene S. Domalski and Elizabeth D. Hearing
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
S°liquid | 127.4 | cal/mol*K | N/A | van der Vis, Cordfunke, et al., 1992 |
Constant pressure heat capacity of liquid
Cp,liquid (cal/mol*K) | Temperature (K) | Reference | Comment |
---|---|---|---|
87.09 | 298.15 | van der Vis, Cordfunke, et al., 1992 | T = 10 to 440 K. Cp/R(liq) = 2.49615x105(T/K)-2 + 70.8549x10-3 + 19.9007 (193 to 362 K), where R = 8.3144 J/mol*K. |
84.15 | 298.15 | Nkinamubanzi, Charlet, et al., 1985 |
Gas phase ion energetics data
Go To: Top, Condensed phase thermochemistry data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Sharon G. Lias, Rhoda D. Levin, and Sherif A. Kafafi
Ionization energy determinations
IE (eV) | Method | Reference | Comment |
---|---|---|---|
9.77 | PE | Green, Lappert, et al., 1971 | Vertical value |
References
Go To: Top, Condensed phase thermochemistry data, Gas phase ion energetics data, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
van der Vis, Cordfunke, et al., 1992
van der Vis, M.G.M.; Cordfunke, E.H.P.; Konings, R.J.M.; van den Berg, G.J.K.; van Miltenburg, J.C.,
Tetraethoxysilane, Si(OC2H5)4: heat capacity and thermodynamic properties at temperatures from 0 to 440 K,
J. Chem. Thermodynam., 1992, 24, 1103-1108. [all data]
Nkinamubanzi, Charlet, et al., 1985
Nkinamubanzi, P.; Charlet, G.; Delmas, G.,
Excess enthalpies, excess heat capacities and excess volumes of tetraalkoxysilanes with cyclohexane and carbon tetrachloride,
Fluid Phase Equilibria, 1985, 20, 57-73. [all data]
Green, Lappert, et al., 1971
Green, M.C.; Lappert, M.F.; Pedley, J.B.; Schmidt, W.; Wilkins, B.T.,
Photoelectron spectra energy level trends in MenSiCl4-n and related series,
J. Organomet. Chem., 1971, 31, 55. [all data]
Notes
Go To: Top, Condensed phase thermochemistry data, Gas phase ion energetics data, References
- Symbols used in this document:
Cp,liquid Constant pressure heat capacity of liquid S°liquid Entropy of liquid at standard conditions - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.