Silane, tetraethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas phase ion energetics data

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
LLK - Sharon G. Lias, Rhoda D. Levin, and Sherif A. Kafafi
RDSH - Henry M. Rosenstock, Keith Draxl, Bruce W. Steiner, and John T. Herron

Ionization energy determinations

IE (eV) Method Reference Comment
8.9PEPotzinger, Ritter, et al., 1975LLK
10.5EIdeRidder and Dijkstra, 1967RDSH
9.8PEBeltram, Fehlner, et al., 1980Vertical value; LLK

Appearance energy determinations

Ion AE (eV) Other Products MethodReferenceComment
C2H5Si+19.4?EIdeRidder and Dijkstra, 1967RDSH
C2H7Si+11.8?EIdeRidder and Dijkstra, 1967RDSH
C4H11Si+12.5?EIdeRidder and Dijkstra, 1967RDSH
C6H15Si+10.0 ± 0.1C2H5EIPotzinger, Ritter, et al., 1975LLK
C6H15Si+11.0?EIdeRidder and Dijkstra, 1967RDSH
SiH+26.8?EIdeRidder and Dijkstra, 1967RDSH
SiH2+25.7?EIdeRidder and Dijkstra, 1967RDSH
SiH3+20.6?EIdeRidder and Dijkstra, 1967RDSH
Si+28.0?EIdeRidder and Dijkstra, 1967RDSH

Mass spectrum (electron ionization)

Go To: Top, Gas phase ion energetics data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Japan AIST/NIMC Database- Spectrum MS-IW-7605
NIST MS number 227699

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


References

Go To: Top, Gas phase ion energetics data, Mass spectrum (electron ionization), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Potzinger, Ritter, et al., 1975
Potzinger, P.; Ritter, A.; Krause, J., Massenspektrometrische Bestimmung von Bindungsenergien in siliciumorganischen Verbindungen, Z. Naturforsch. A:, 1975, 30, 347. [all data]

deRidder and Dijkstra, 1967
deRidder, J.J.; Dijkstra, G., Mass spectra of the tetramethyl and tetraethyl compounds of carbon, silicon, germanium, tin and lead, Rec. Trav. Chim., 1967, 86, 737. [all data]

Beltram, Fehlner, et al., 1980
Beltram, G.; Fehlner, T.P.; Mochida, K.; Kochi, J.K., UV photoelectron spectra of group IV alkyl hydrides, J. Electron Spectrosc. Relat. Phenom., 1980, 18, 153. [all data]


Notes

Go To: Top, Gas phase ion energetics data, Mass spectrum (electron ionization), References