Ethylene, 1,1-dibromo-
- Formula: C2H2Br2
- Molecular weight: 185.845
- IUPAC Standard InChIKey: IWHJPYXAFGKABF-UHFFFAOYSA-N
- CAS Registry Number: 593-92-0
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: 1,1-dibromoethylene; Ethene, 1,1-dibromo-
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Options:
Phase change data
Go To: Top, Gas phase ion energetics data, IR Spectrum, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Robert L. Brown and Stephen E. Stein
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
Tboil | 365.2 | K | N/A | Weast and Grasselli, 1989 |
Gas phase ion energetics data
Go To: Top, Phase change data, IR Spectrum, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
LBLHLM - Sharon G. Lias, John E. Bartmess, Joel F. Liebman, John L. Holmes, Rhoda D. Levin, and W. Gary Mallard
Ionization energy determinations
IE (eV) | Method | Reference | Comment |
---|---|---|---|
9.78 | PE | Von Niessen, Asbrink, et al., 1982 | LBLHLM |
IR Spectrum
Go To: Top, Phase change data, Gas phase ion energetics data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Coblentz Society, Inc.
Gas Phase Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Notice: Except where noted, spectra from this collection were measured on dispersive instruments, often in carefully selected solvents, and hence may differ in detail from measurements on FTIR instruments or in other chemical environments. More information on the manner in which spectra in this collection were collected can be found here.
Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.
Additional Data
View scan of original (hardcopy) spectrum.
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Owner | Copyright (C) 1987 by the Coblentz Society Collection (C) 2018 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | DOW CHEMICAL COMPANY |
Source reference | COBLENTZ NO. 8857 |
Date | 1964 |
Name(s) | 1,1-dibromoethylene 1,1-DIBROMO ETHYLENE |
State | GAS (50 mmHg, N2 ADDED, TOTAL PRESSURE 600 mmHg) |
Instrument | DOW KBr FOREPRISM-GRATING |
Instrument parameters | GRATING CHANGED AT 5.0, 7.5, 15.0 MICRON |
Path length | 5 CM |
Resolution | 2 |
Sampling procedure | TRANSMISSION |
Data processing | DIGITIZED BY COBLENTZ SOCIETY (BATCH II) FROM HARD COPY |
References
Go To: Top, Phase change data, Gas phase ion energetics data, IR Spectrum, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]
Von Niessen, Asbrink, et al., 1982
Von Niessen, W.; Asbrink, L.; Bieri, G.,
30.4 nm He(II) Photoelectron spectra of organic molecules. Part VI. Halogeno-compounds (C,H,X: X = Cl, Br, I),
J. Electron Spectrosc. Relat. Phenom., 1982, 26, 173. [all data]
Notes
Go To: Top, Phase change data, Gas phase ion energetics data, IR Spectrum, References
- Symbols used in this document:
Tboil Boiling point - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.