HN3+
- Formula: HN3+
- Molecular weight: 43.0275
- CAS Registry Number: 58852-14-5
- Information on this page:
- Options:
Vibrational and/or electronic energy levels
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Marilyn E. Jacox
State: E
Energy (cm-1) |
Med. | Transition | λmin (nm) |
λmax (nm) |
References | ||
---|---|---|---|---|---|---|---|
Tx = 87620 ± 1000 | gas | Bastide and Maier, 1976 | |||||
State: D
Energy (cm-1) |
Med. | Transition | λmin (nm) |
λmax (nm) |
References | ||
---|---|---|---|---|---|---|---|
Tx = 77130 ± 1000 | gas | Lee, Colton, et al., 1975 | |||||
Bastide and Maier, 1976 | |||||||
State: C
Energy (cm-1) |
Med. | Transition | λmin (nm) |
λmax (nm) |
References | ||
---|---|---|---|---|---|---|---|
Tx = 48890 ± 320 | gas | Cradock, Ebsworth, et al., 1972 | |||||
Lee, Colton, et al., 1975 | |||||||
Bastide and Maier, 1976 | |||||||
State: B
Energy (cm-1) |
Med. | Transition | λmin (nm) |
λmax (nm) |
References | ||
---|---|---|---|---|---|---|---|
To = 38000 ± 320 | gas | Cradock, Ebsworth, et al., 1972 | |||||
Lee, Colton, et al., 1975 | |||||||
Bastide and Maier, 1976 | |||||||
Vib. sym. |
No. | Approximate type of mode |
cm-1 | Med. | Method | References | |
---|---|---|---|---|---|---|---|
a' | 2 | N3 a-stretch | 2380 ± 80 | gas | PE | Cradock, Ebsworth, et al., 1972 Lee, Colton, et al., 1975 Bastide and Maier, 1976 | |
4 | N3 s-stretch | 930 ± 80 | gas | PE | Cradock, Ebsworth, et al., 1972 Lee, Colton, et al., 1975 Bastide and Maier, 1976 | ||
5 | N3 deform. | 570 ± 80 | gas | PE | Cradock, Ebsworth, et al., 1972 Lee, Colton, et al., 1975 Bastide and Maier, 1976 | ||
State: A
Energy (cm-1) |
Med. | Transition | λmin (nm) |
λmax (nm) |
References | ||
---|---|---|---|---|---|---|---|
To = 7750 ± 320 | gas | Cradock, Ebsworth, et al., 1972 | |||||
Lee, Colton, et al., 1975 | |||||||
Bastide and Maier, 1976 | |||||||
Vib. sym. |
No. | Approximate type of mode |
cm-1 | Med. | Method | References | |
---|---|---|---|---|---|---|---|
a' | 5 | N3 deform. | 480 | T | gas | PE | Cradock, Ebsworth, et al., 1972 Lee, Colton, et al., 1975 Bastide and Maier, 1976 |
State: X
Vib. sym. |
No. | Approximate type of mode |
cm-1 | Med. | Method | References | |
---|---|---|---|---|---|---|---|
a' | 2 | N3 a-stretch | 1850 ± 80 | gas | PE | Cradock, Ebsworth, et al., 1972 Bastide and Maier, 1976 | |
4 | N3 s-stretch | 850 ± 80 | gas | PE | Cradock, Ebsworth, et al., 1972 Bastide and Maier, 1976 | ||
Additional references: Jacox, 1994, page 161
Notes
T | Tentative assignment or approximate value |
o | Energy separation between the v = 0 levels of the excited and electronic ground states. |
x | Energy separation between the band maximum of the excited electronic state and the v = 0 level of the ground state. |
References
Go To: Top, Vibrational and/or electronic energy levels, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Bastide and Maier, 1976
Bastide, J.; Maier, J.P.,
Electronic states of the radical cations of the 1,3-dipoles: HCNO, CH2N2, and N3H, studied by photoelectron spectroscopy,
Chem. Phys., 1976, 12, 177. [all data]
Lee, Colton, et al., 1975
Lee, T.H.; Colton, R.J.; White, M.G.; Rabalais, J.W.,
Electronic structure of hydrazoic acid and the azide ion from x-ray ultraviolet electron spectroscopy,
J. Am. Chem. Soc., 1975, 97, 4845. [all data]
Cradock, Ebsworth, et al., 1972
Cradock, S.; Ebsworth, E.A.V.; Murdoch, J.D.,
J. Chem. Soc., 1972, Faraday Trans. 2 68, 86. [all data]
Jacox, 1994
Jacox, M.E.,
Vibrational and electronic energy levels of polyatomic transient molecules, American Chemical Society, Washington, DC, 1994, 464. [all data]
Notes
Go To: Top, Vibrational and/or electronic energy levels, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.