NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas phase ion energetics data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
LLK - Sharon G. Lias, Rhoda D. Levin, and Sherif A. Kafafi

View reactions leading to C4H8O+ (ion structure unspecified)

Ionization energy determinations

IE (eV) Method Reference Comment
10.00PEMcAlduff and Houk, 1977LLK
10.00PEMcAlduff and Houk, 1977Vertical value; LLK

Gas Chromatography

Go To: Top, Gas phase ion energetics data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-10170.534.4Boneva and Dimov, 1987100. m/0.27 mm/0.9 μm
CapillaryOV-10180.534.7Boneva and Dimov, 1987100. m/0.27 mm/0.9 μm
CapillaryOV-10190.535.0Boneva and Dimov, 1987100. m/0.27 mm/0.9 μm
PackedApiezon L120.507.Bogoslovsky, Anvaer, et al., 1978Celite 545
PackedApiezon L160.510.Bogoslovsky, Anvaer, et al., 1978Celite 545

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryMethyl Silicone60.500.Cao and Zhang, 2006Column length: 50. m; Column diameter: 0.25 mm
CapillaryMethyl Silicone70.500.Cao and Zhang, 2006Column length: 50. m; Column diameter: 0.25 mm
CapillaryMethyl Silicone80.500.Cao and Zhang, 2006Column length: 50. m; Column diameter: 0.25 mm
PackedApieson L120.513.Kurdina, Markovich, et al., 1969not specified, not specified

References

Go To: Top, Gas phase ion energetics data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

McAlduff and Houk, 1977
McAlduff, E.J.; Houk, K.N., Photoelectron spectra of substituted oxiranes and thiiranes. Substituent effects on ionization potentials involving σ orbitals, Can. J. Chem., 1977, 55, 318. [all data]

Boneva and Dimov, 1987
Boneva, S.; Dimov, N., Gas chromatographic separation of C4-C5 epoxides on a glass capillary column coated with OV-101 methylsilicone, Chromatographia, 1987, 23, 10, 770-772, https://doi.org/10.1007/BF02312672 . [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Cao and Zhang, 2006
Cao, J.; Zhang, H., Inquire into qualitative analysis of epoxyalkyl isomeride, Contemporary Chem. Ind. (Chinese), 2006, 35, 5, 374-377. [all data]

Kurdina, Markovich, et al., 1969
Kurdina, Z.G.; Markovich, V.E.; Sakharov, V.M., Gas chromatography of cyclic O-containing compounds in Gas chromatography, Issue # 10, NIITEKhim, Moscow, 1969, 128-133. [all data]


Notes