Cyclopentene, 1-pentyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin S.A. Rang et al., IR & MS of Unsatd. Hydrocarbons, 1977
NIST MS number 142665

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySqualane100.1040.Bogoslovsky, Anvaer, et al., 1978 
CapillarySqualane60.1034.Bogoslovsky, Anvaer, et al., 1978 
CapillarySqualane80.1037.Bogoslovsky, Anvaer, et al., 1978 
CapillarySqualane100.1036.Rang, Orav, et al., 1977Nitrogen or helium; Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane100.1037.Dielmann, Schwengers, et al., 1974Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane80.1034.Dielmann, Schwengers, et al., 1974Column length: 100. m; Column diameter: 0.25 mm
CapillaryApiezon L100.1060.Eisen, Orav, et al., 1972Column length: 45. m; Column diameter: 0.25 mm
CapillaryApiezon L120.1063.Eisen, Orav, et al., 1972Column length: 45. m; Column diameter: 0.25 mm
CapillarySqualane60.1031.4Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillarySqualane80.1034.3Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillarySqualane60.1031.Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm
CapillarySqualane80.1034.Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryPEG 4000100.1159.Rang, Orav, et al., 1988 
CapillaryPEG 4000110.1166.Rang, Orav, et al., 1988 
CapillaryPEG 4000120.1169.Rang, Orav, et al., 1988 
CapillaryPEG 4000150.1172.Rang, Orav, et al., 1988 
CapillaryPEG 4000160.1183.Rang, Orav, et al., 1988 
CapillaryPEG 400080.1152.Rang, Orav, et al., 1988 
CapillaryPEG-20M100.1155.Rang, Orav, et al., 1988 
CapillaryPEG-20M110.1160.Rang, Orav, et al., 1988 
CapillaryPEG-20M120.1163.Rang, Orav, et al., 1988 
CapillaryPEG-20M130.1167.Rang, Orav, et al., 1988 
CapillaryPEG-20M140.1171.Rang, Orav, et al., 1988 
CapillaryPEG-20M80.1148.Rang, Orav, et al., 1988 
CapillaryPEG-20M90.1152.Rang, Orav, et al., 1988 
CapillaryPEG-20M100.1155.4Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M110.1159.5Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M120.1163.2Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M130.1166.8Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M140.1171.4Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M80.1147.5Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG-20M90.1151.5Orav, Kuningas, et al., 1982He; Column length: 100. m; Column diameter: 0.25 mm
CapillaryPEG 4000100.1166.Rang, Orav, et al., 1977Nitrogen or Helium; Column length: 45. m; Column diameter: 0.25 mm
CapillaryPolyethylene Glycol 4000100.1165.6Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPolyethylene Glycol 400060.1151.8Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPolyethylene Glycol 400080.1160.2Eisen, Orav, et al., 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPEG 4000100.1165.6Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPEG 400060.1151.8Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm
CapillaryPEG 400080.1160.2Orav and Eisen, 1972Column length: 80. m; Column diameter: 0.25 mm

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillarySP-21001038.Alencar, Alves, et al., 1983He, 4. K/min; Column length: 30. m; Column diameter: 0.25 mm; Tstart: 40. C; Tend: 250. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySqualane1032.Chen, 2008Program: not specified
CapillaryDB-5 MS1054.Luo and Agnew, 200130. m/0.25 mm/1.0 μm, Helium; Program: not specified

Normal alkane RI, polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-Wax1114.Chung, Eiserich, et al., 199360. C @ 4. min, 3. K/min; Column length: 60. m; Column diameter: 0.25 mm; Tend: 220. C

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Rang, Orav, et al., 1977
Rang, S.; Orav, A.; Kuningas, K.; Eisen, O., Capillary Gas Chromatography of Monosubstituted Cyclopentenes and Cyclohexenes, Chromatographia, 1977, 10, 3, 115-122, https://doi.org/10.1007/BF02297862 . [all data]

Dielmann, Schwengers, et al., 1974
Dielmann, G.; Schwengers, D.; Schomburg, G., Gas-chromatographische Retentionsdaten und Strukture chemischer Verbindungen Gesättigte und ungesättigte alkylsubstituierte Cyclopentane und Methylcyclopentane, Chromatographia, 1974, 7, 5, 215-224, https://doi.org/10.1007/BF02321771 . [all data]

Eisen, Orav, et al., 1972
Eisen, O.; Orav, A.; Rang, S., Identifizierung von Normal-Alkenen, Cyclopentenen und -Hexenen mittels Kapillar-Gas-Chromatographie. Identification des alcènes, cyclopentènes et -hexènes à l'aide de la chromatogrpahie en phase gazeuse sur colonne capillaire, Chromatographia, 1972, 5, 11, 229-239, https://doi.org/10.1007/BF02270600 . [all data]

Orav and Eisen, 1972
Orav, A.; Eisen, O., The retention indexes for alkenes, alkynes and cyclenes on capillary columns, Izv. Akad. Nauk Est. SSR, Khim. Geol., 1972, 21, 1, 39-47. [all data]

Rang, Orav, et al., 1988
Rang, S.A.; Orav, A.E.; Kuningas, K.R.; Meister, A.E.; Strense, T.V.; Eisen, O.G., Gas-Chromatographic Characteristics of unsaturated hydrocarbons, Academy of Sciences of Estonia SSR, Tallinn, Estonia SSR, 1988, 208. [all data]

Orav, Kuningas, et al., 1982
Orav, A.; Kuningas, K.; Rang, S.; Eisen, O., Capillary gas chromatography of monosubstituted cyclopentenes and cyclohexenes C8-C15 on polyethylene glycol 20M, Eesti NSV Tead. Akad. Toim. Keem., 1982, 40-49. [all data]

Alencar, Alves, et al., 1983
Alencar, J.W.; Alves, P.B.; Craveiro, A.A., Pyrolysis of tropical vegetable oils, J. Agric. Food Chem., 1983, 31, 6, 1268-1270, https://doi.org/10.1021/jf00120a031 . [all data]

Chen, 2008
Chen, H.-F., Quantitative prediction of gas chromatography retention indices with support vector machines, radial basis neutral networks and multiple linear regression, Anal. Chim. Acta, 2008, 609, 1, 24-36, https://doi.org/10.1016/j.aca.2008.01.003 . [all data]

Luo and Agnew, 2001
Luo, J.; Agnew, M.P., Gas characteristics before and after biofiltration treating odorous emissions from animal rendering processes, Environ. Technol., 2001, 22, 9, 1091-1103, https://doi.org/10.1080/09593332208618220 . [all data]

Chung, Eiserich, et al., 1993
Chung, T.Y.; Eiserich, J.P.; Shibamoto, T., Volatile compounds identified in headspace samples of peanut oil heated under temperatures ranging from 50 to 200 °C, J. Agric. Food Chem., 1993, 41, 9, 1467-1470, https://doi.org/10.1021/jf00033a022 . [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References