Methyl anthranilate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase VF-5MSHP-5DB-1DB-5HP-5MS
Column length (m) 30.30.30.30.30.
Carrier gas HeN2HeN2He
Substrate      
Column diameter (mm) 0.250.250.250.320.25
Phase thickness (μm) 0.250.250.251.0.25
Tstart (C) 60.50.40.40.60.
Tend (C) 270.220.250.230.250.
Heat rate (K/min)  5.3.4.4.
Initial hold (min)  10. 2.2.
Final hold (min)   20.10.20.
I 1373.1338.1332.1354.1338.
ReferenceTodua, 2011Flamini, Tebano, et al., 2007Fanciullino, Gancel, et al., 2005Fang and Qian, 2005Pino, Mesa, et al., 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5DB-1DB-1OV-101OV-101
Column length (m) 30.30.60.15.15.
Carrier gas N2HeHe  
Substrate      
Column diameter (mm) 0.250.250.250.320.32
Phase thickness (μm) 0.250.250.25  
Tstart (C) 60.40.50.35.35.
Tend (C) 220.250.250.250.250.
Heat rate (K/min) 5.3.3.56.6.
Initial hold (min) 10. 5.3.3.
Final hold (min)  20.   
I 1342.1332.1328.1316.1320.
ReferenceFlamini, Luigi Cioni, et al., 2003Gancel, Ollitrault, et al., 2003Stashenko, Prada, et al., 1996Chisholm, Guiher, et al., 1994Chisholm, Guiher, et al., 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPacked
Active phase CP Sil 5 CBCP Sil 5 CBSE-30
Column length (m) 26.26. 
Carrier gas    
Substrate   Celite
Column diameter (mm) 0.320.32 
Phase thickness (μm) 1.251.25 
Tstart (C) 100.100.75.
Tend (C) 250.250.228.
Heat rate (K/min) 10.10. 
Initial hold (min)    
Final hold (min)    
I 1329.1336.1325.
ReferenceHalket and Schulten, 1985Halket and Schulten, 1985van den Dool and Kratz, 1963
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Todua, 2011
Todua, N.G., Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2011. [all data]

Flamini, Tebano, et al., 2007
Flamini, G.; Tebano, M.; Cioni, P.L., Volatiles emission patterns of different plant organs and pollen of Citrus limon, Anal. Chim. Acta., 2007, 589, 1, 120-124, https://doi.org/10.1016/j.aca.2007.02.053 . [all data]

Fanciullino, Gancel, et al., 2005
Fanciullino, A.-L.; Gancel, A.-L.; Froelicher, Y.; Luro, F.; Ollitrault, P.; Brillouet, J.-M., Effects of Nucleo-cytoplasmic Interactions on Leaf Volatile Compounds from Citrus Somatic Diploid Hybrids, J. Agric. Food Chem., 2005, 53, 11, 4517-4523, https://doi.org/10.1021/jf0502855 . [all data]

Fang and Qian, 2005
Fang, Y.; Qian, M., Aroma compounds in Oregon Pinot Noir wine determined by aroma extract dilution analysis (AEDA), Flavour Fragr. J., 2005, 20, 1, 22-29, https://doi.org/10.1002/ffj.1551 . [all data]

Pino, Mesa, et al., 2005
Pino, J.A.; Mesa, J.; Muñoz, Y.; Martí, M.P.; Marbot, R., Volatile components from mango (Mangifera indica L.) cultivars, J. Agric. Food Chem., 2005, 53, 6, 2213-2223, https://doi.org/10.1021/jf0402633 . [all data]

Flamini, Luigi Cioni, et al., 2003
Flamini, G.; Luigi Cioni, P.; Morelli, I., Short communication. Use of solid-phase micro-extraction as a sampling technique in the determination of volatiles emitted by flowers, isolated flower parts and pollen, J. Chromatogr. A, 2003, 998, 1-2, 229-233, https://doi.org/10.1016/S0021-9673(03)00641-1 . [all data]

Gancel, Ollitrault, et al., 2003
Gancel, A.-L.; Ollitrault, P.; Froelicher, Y.; Tomi, F.; Jacquemond, C.; Luro, F.; Brillouet, J.-M., Leaf volatile compounds of seven citrus somatic tetraploid hybrids sharing willow leaf mandarin (Citrus deliciosa Ten.) as their common parent, J. Agric. Food Chem., 2003, 51, 20, 6006-6013, https://doi.org/10.1021/jf0345090 . [all data]

Stashenko, Prada, et al., 1996
Stashenko, E.E.; Prada, N.Q.; Martínez, J.R., HRGC/FID/NP and HRGC/MSD study of Colombian Ylang-Ylang (Cananga odorata) oils obtained by different extraction techniques, J. Hi. Res. Chromatogr., 1996, 19, 6, 353-358, https://doi.org/10.1002/jhrc.1240190609 . [all data]

Chisholm, Guiher, et al., 1994
Chisholm, M.G.; Guiher, L.A.; Vonah, T.M.; Beaumont, J.L., Comparison of some French-American hybrid wines with white Riesling using gas chromatography-olfactometry, Am. J. Enol. Vitic, 1994, 45, 2, 201-212. [all data]

Halket and Schulten, 1985
Halket, J.M.; Schulten, H.-R., Thick-film capillary column gas chromatography-field ionization mass spectrometry: A complementary technique for the rapid analysis of volatiles, J. Chromatogr., 1985, 322, 200-205, https://doi.org/10.1016/S0021-9673(01)97672-1 . [all data]

van den Dool and Kratz, 1963
van den Dool, H.; Kratz, P. Dec., A generalization of the retention index system including linear temperature programmed gas-liquid partition chromatography, J. Chromatogr., 1963, 11, 463-471, https://doi.org/10.1016/S0021-9673(01)80947-X . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References