Trinitrotoluene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas phase thermochemistry data

Go To: Top, IR Spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein

Quantity Value Units Method Reference Comment
Δfgas24.1 ± 3.5kJ/molCcbLenchitz, Velicky, et al., 1971 

IR Spectrum

Go To: Top, Gas phase thermochemistry data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Timothy J. Johnson, Tanya L. Myers, Yin-Fong Su, Russell G. Tonkyn, Molly Rose K. Kelly-Gorham, and Tyler O. Danby

Condensed Phase Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

IR spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Detailed documentation for this spectrum is available.

Owner Public domain
Origin Pacific Northwest National Laboratory Under IARPA Contract
Date March 2017
State solid
Instrument Bruker IR Cube FTIR
Aperture 6 mm
External diffuse reflectance accessory A 562-G integrating sphere
Beam splitter Ge on KBr
Diameter of detector port in sphere 2×2 mm, 60° field of view MCT
Sphere diameter 75 mm
Acquisition mode double-sided, forward-backward
Scanner velocity 40 kHz
Co-added scans 2048
Phase resolution 32.00
Phase correction Mertz
Zero filling
Spectral range 7,500 to 600 cm-1 saved; 7500 to 600 cm-1 reported
Resolution 0.96450084
Spectral resolution 4 cm-1
Wavenumber accuracy ± 0.4 cm-1
Apodization function Blackman-Harris 3-term
Low-pass filter Open
Switch gain on 512 points

Gas Chromatography

Go To: Top, Gas phase thermochemistry data, IR Spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryDB-5140.1707.07Hobbs and Conde, 199230. m/0.25 mm/0.25 μm
CapillaryDB-5140.1714.08Hobbs and Conde, 199230. m/0.25 mm/0.25 μm

Kovats' RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
PackedOV-1011693.Alley and Dykes, 19726. K/min; Tstart: 70. C; Tend: 220. C

Kovats' RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone1704.Staples, 2005Column diameter: 0.25 mm; Program: not specified

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51708.67Hobbs and Conde, 199230. m/0.25 mm/0.25 μm, 5. K/min; Tstart: 40. C; Tend: 300. C
CapillaryDB-51717.67Hobbs and Conde, 199230. m/0.25 mm/0.25 μm, 5. K/min; Tstart: 40. C; Tend: 300. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51704.Staples, 2004He; Program: not specified
CapillaryDB-51709.Staples, 2004He; Program: not specified

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-5MS287.66Chen, Keeran, et al., 200230. m/0.25 mm/0.5 μm, 40. C @ 1. min, 10. K/min; Tend: 310. C

References

Go To: Top, Gas phase thermochemistry data, IR Spectrum, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Lenchitz, Velicky, et al., 1971
Lenchitz, C.; Velicky, R.W.; Silvestro, G.; Schlosberg, L.P., Thermodynamic properties of several nitrotoluenes, J. Chem. Thermodyn., 1971, 3, 689-692. [all data]

Hobbs and Conde, 1992
Hobbs, J.R.; Conde, E.P., Gas chromatographic retention indices of explosives and nitro-compounds in Advances in Analysis and Detection of Explosives: Proceedings of the 4th International Symposium on Analysis of Detection of Explosives, September 7-10, 1992, Jerusalem Israel, J. Yinon, ed(s)., Kluwer Academic Publishers, Netherlands, 1992, 153-164. [all data]

Alley and Dykes, 1972
Alley, B.J.; Dykes, H.W.H., Gas-Liquid Chromatographic Determination of Nitrate Esters,Stabilizers and Plasticizers in Nitrocellulose-Base Propellants, J. Chromatogr., 1972, 71, 1, 23-37, https://doi.org/10.1016/S0021-9673(01)85687-9 . [all data]

Staples, 2005
Staples, E.J., Ultrahigh-speed chromatography and virtual chemical sensors for detecting explosives and chemical warfare agents, IEEE Sens. J., 2005, 5, 4, 622-631, https://doi.org/10.1109/JSEN.2005.850990 . [all data]

Staples, 2004
Staples, E.J., Analysis of odors from explosives using an electronic nose, 2004, retrieved from http://www.estcal.com/TechPapers/OdorsofExplosives.doc. [all data]

Chen, Keeran, et al., 2002
Chen, P.H.; Keeran, W.S.; Van Ausdale, W.A.; Schindler, D.R.; Roberts, D.W., Application of Lee retention indices to the confirmation of tentatively identified compounds from GC/MS analysis of environmental samples, Technical paper, Analytical Services Division, Environmental ScienceEngineering, Inc, PO Box 1703, Gainesville, FL 32602, 2002, 11. [all data]


Notes

Go To: Top, Gas phase thermochemistry data, IR Spectrum, Gas Chromatography, References