Trisiloxane, octamethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas phase ion energetics data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: William E. Acree, Jr., James S. Chickos

Enthalpy of vaporization

ΔvapH (kJ/mol) Temperature (K) Method Reference Comment
43.2361.EBFlaningam, 1986Based on data from 346. to 446. K.
40.2381.N/ASkorokhodov, Ditsent, et al., 1971Based on data from 345. to 417. K.

Gas phase ion energetics data

Go To: Top, Phase change data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
LBLHLM - Sharon G. Lias, John E. Bartmess, Joel F. Liebman, John L. Holmes, Rhoda D. Levin, and W. Gary Mallard
LLK - Sharon G. Lias, Rhoda D. Levin, and Sherif A. Kafafi

Ionization energy determinations

IE (eV) Method Reference Comment
10.04PEErmakov, Kirichenko, et al., 1982Vertical value; LBLHLM

Appearance energy determinations

Ion AE (eV) Other Products MethodReferenceComment
C3H9SiO+21.8 ± 0.2?EIBorossay, Csakvari, et al., 1971LLK
C3H9Si+15.8 ± 0.2?EIBorossay, Csakvari, et al., 1971LLK

IR Spectrum

Go To: Top, Phase change data, Gas phase ion energetics data, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compiled by: Coblentz Society, Inc.


Mass spectrum (electron ionization)

Go To: Top, Phase change data, Gas phase ion energetics data, IR Spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin R.W.CRAWFORD UNIV. OF CALIFORNIA, LIVERMORE, CALIFORNIA, USA
NIST MS number 11382

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Phase change data, Gas phase ion energetics data, IR Spectrum, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryUltra-11031.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11031.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11034.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11034.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11038.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11038.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)

References

Go To: Top, Phase change data, Gas phase ion energetics data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Flaningam, 1986
Flaningam, Ora L., Vapor pressures of poly(dimethylsiloxane) oligomers, J. Chem. Eng. Data, 1986, 31, 3, 266-272, https://doi.org/10.1021/je00045a002 . [all data]

Skorokhodov, Ditsent, et al., 1971
Skorokhodov, I.I.; Ditsent, V.E.; Teret'eva, N.A.; Zolotarev, M.N., Russ. J. Phys. Chem., 1971, 45, 6, 902. [all data]

Ermakov, Kirichenko, et al., 1982
Ermakov, A.I.; Kirichenko, E.A.; Pimkin, N.I.; Chizhov, Y.V.; Kleimenov, V.I., Photoelectronic spectra and electronic structure of organotri- and organotetrasiloxanes of linear and cyclic structure, Zh. Strukt. Khim., 1982, 23, 61. [all data]

Borossay, Csakvari, et al., 1971
Borossay, J.; Csakvari, B.; Szepes, L., Determination of bond energies of organic silicon compounds on the basis of appearance potentials, Int. J. Mass Spectrom. Ion Phys., 1971, 7, 47. [all data]

Kazuyoshi, Seiichi, et al., 2000
Kazuyoshi, N.; Seiichi, Y.; Kazuo, K.; Katsumi, I.; Okihiko, S., Polymer analysis by improved pyrolysis gas chromatography hyphenated with four specific detectors, J. Soc. Cosmet. Chem. Jpn., 2000, 34, 2, 142-151, https://doi.org/10.5107/sccj.34.142 . [all data]


Notes

Go To: Top, Phase change data, Gas phase ion energetics data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References