Pentadecane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Critical temperature

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Tc (K) Reference Comment
708. ± 2.Ambrose and Tsonopoulos, 1995 
708.4Anselme, Gude, et al., 1990Uncertainty assigned by TRC = 1.3 K; TRC
707.5Rosenthal and Teja, 1989Uncertainty assigned by TRC = 0.7 K; TRC
708.4Teja, Gude, et al., 1989Uncertainty assigned by TRC = 1.2 K; TRC
707.8Teja, Lee, et al., 1989TRC
706.3Teja and Smith, 1987Uncertainty assigned by TRC = 0.4 K; TRC
706.4Smith, Anselme, et al., 1986Uncertainty assigned by TRC = 1.5 K; TRC
707.Majer and Svoboda, 1985 
709.2Mogollon, Kay, et al., 1982Uncertainty assigned by TRC = 1. K; TRC
709.2Mogollon and Kay, 1973Uncertainty assigned by TRC = 1. K; extrapolated to zero time to correct for decompostion; TRC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


References

Go To: Top, Critical temperature, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ambrose and Tsonopoulos, 1995
Ambrose, D.; Tsonopoulos, C., Vapor-Liquid Critical Properties of Elements and Compounds. 2. Normal Alkenes, J. Chem. Eng. Data, 1995, 40, 531-546. [all data]

Anselme, Gude, et al., 1990
Anselme, M.J.; Gude, M.; Teja, A.S., The Critical Temperatures and Densities of the n-Alkanes from Pentane to Octadecane, Fluid Phase Equilib., 1990, 57, 317-26. [all data]

Rosenthal and Teja, 1989
Rosenthal, D.J.; Teja, A.S., The Critical Properties of n-Alkanes Using a Low-Residence Time Flow Apparatus, AIChE J., 1989, 35, 1829. [all data]

Teja, Gude, et al., 1989
Teja, A.S.; Gude, M.; Rosenthal, D.J., Novel methods for the measurement of the critical properties of thermally unstable fluids, Fluid Phase Equilib., 1989, 52, 193. [all data]

Teja, Lee, et al., 1989
Teja, A.S.; Lee, R.J.; Rosenthal, D.J.; Anselme, M.J., Correlation of the Critical Properties of Alkanes and Alkanols in 5th IUPAC Conference on Alkanes and AlkanolsGradisca, 1989. [all data]

Teja and Smith, 1987
Teja, A.S.; Smith, R.L., Critical properties of thermally unstable substances from mixture data, AIChE J., 1987, 33, 1560. [all data]

Smith, Anselme, et al., 1986
Smith, R.L.; Anselme, M.; Teja, A.S., Proc. World Congress III Chem. Eng., Tokyo, Vol. II, 1986. [all data]

Majer and Svoboda, 1985
Majer, V.; Svoboda, V., Enthalpies of Vaporization of Organic Compounds: A Critical Review and Data Compilation, Blackwell Scientific Publications, Oxford, 1985, 300. [all data]

Mogollon, Kay, et al., 1982
Mogollon, E.; Kay, W.B.; Teja, A.S., Modified sealed-tube method for the determination of critical temperature., Ind. Eng. Chem. Fundam., 1982, 21, 2, 173-5. [all data]

Mogollon and Kay, 1973
Mogollon, E.; Kay, W.B., Unpublished manuscript 1973, 1973. [all data]


Notes

Go To: Top, Critical temperature, References