Benzenamine, N,4-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


IR Spectrum

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Coblentz Society, Inc.

Condensed Phase Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

IR spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Notice: Except where noted, spectra from this collection were measured on dispersive instruments, often in carefully selected solvents, and hence may differ in detail from measurements on FTIR instruments or in other chemical environments. More information on the manner in which spectra in this collection were collected can be found here.

Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.

Additional Data

View scan of original (hardcopy) spectrum.

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Owner COPYRIGHT (C) 1988 by COBLENTZ SOCIETY INC.
Collection (C) 2018 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin DOW CHEMICAL COMPANY
Source reference COBLENTZ NO. 6277
Date 1960/02/23
Name(s) N-methyl-N-(4-methylphenyl)amine
N,4-dimethylaniline
State SOLUTION (10% CCl4 FOR 3800-1330, 10% CS2 FOR 1330-420 CM-1)
Instrument DOW KBr FOREPRISM-GRATING
Instrument parameters BLAZED AT 3.5, 12.0, 20.0 MICRON AND CHANGED AT 5.0, 7.5, 14.9 MICRON
Path length 0.011 CM, 0.011 CM
SPECTRAL CONTAMINATION DUE TO CS2 AROUND 850 CM-1 HAS BEEN SUBTRACTED
Resolution 2
Sampling procedure TRANSMISSION
Data processing DIGITIZED BY COBLENTZ SOCIETY (BATCH I) FROM HARD COPY

This IR spectrum is from the Coblentz Society's evaluated infrared reference spectra collection.


References

Go To: Top, IR Spectrum, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

No reference data available.


Notes

Go To: Top, IR Spectrum, References