Glyoxal


IR Spectrum

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Tanya L. Myers, Russell G. Tonkyn, Ashley M. Oeck, Tyler O. Danby, John S. Loring, Matthew S. Taubman, Stephen W. Sharpe, Jerome C. Birnbaum, and Timothy J. Johnson

Condensed Phase Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

IR spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Detailed documentation for this spectrum is available.

Owner Public domain
Origin Pacific Northwest National Laboratory Under IARPA Contract
Date March 2017
State liquid
Instrument Bruker Tensor 27 FTIR
Instrument resolution 2.0 cm-1
IR source Silicon carbide glow bar
Aperture 3 mm
Beam splitter Broadband potassium bromide (KBr)
Detector DLTGS at room temperature
Scanner velocity 10 kHz
Phase correction Mertz
Interferogram zero fill 4x
Spectral interval after zero fill 0.4823 cm-1
Spectral range 7800 to 400 cm-1 (1.282 to 25 microns)
Resolution 0.4821395
Apodization Norton-Beer, Medium
Folding limits 15802 to 0 cm-1
Number of interferograms averaged per single channel spectrum 128

References

Go To: Top, IR Spectrum, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

No reference data available.


Notes

Go To: Top, IR Spectrum, References