Benzene, 1-(1,5-dimethylhexyl)-4-methyl-


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin NIST Mass Spectrometry Data Center, 2010
NIST MS number 384075

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSF-96150.1448.Maarse, 1975Chromosorb W-AW; Column length: 3.0 m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedCarbowax 20M130.1696.Maarse, 1975Chromosorb W-AW; Column length: 3.0 m

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-1250.03Bastow, Alexander, et al., 19973. K/min; Column length: 60. m; Column diameter: 0.25 mm; Tstart: 70. C; Tend: 300. C
CapillaryDB-1247.98Bastow, Alexander, et al., 19973. K/min; Column length: 60. m; Column diameter: 0.25 mm; Tstart: 70. C; Tend: 300. C
CapillaryDB-5245.40Bastow, Alexander, et al., 19973. K/min; Column length: 40. m; Column diameter: 0.18 mm; Tstart: 70. C; Tend: 300. C
CapillaryDB-5243.24Bastow, Alexander, et al., 19973. K/min; Column length: 40. m; Column diameter: 0.18 mm; Tstart: 70. C; Tend: 300. C

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Maarse, 1975
Maarse, H., Hydrogenolysis of terpenes in the injection port of a gas chromatograph. II. Sesquiterpenes, J. Chromatogr., 1975, 106, 2, 369-384, https://doi.org/10.1016/S0021-9673(00)93846-9 . [all data]

Bastow, Alexander, et al., 1997
Bastow, T.P.; Alexander, R.; Kagi, R.I., Identification and analysis of dihydro-ar-curcumene enantiomers and related compounds in petroleum, Org. Geochem., 1997, 26, 1/2, 79-83, https://doi.org/10.1016/S0146-6380(96)00155-6 . [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References