Ibuprofen
- Formula: C13H18O2
- Molecular weight: 206.2808
- IUPAC Standard InChIKey: HEFNNWSXXWATRW-UHFFFAOYSA-N
- CAS Registry Number: 15687-27-1
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Stereoisomers:
- Other names: Benzeneacetic acid, α-methyl-4-(2-methylpropyl)-; 4-Isobutyl-α-methylphenylacetic acid; α-(p-isobutylphenyl)propionic acid; α-(4-Isobutylphenyl)propionic acid; (.+/-.)-p-Isobutylhydratropic acid; (.+/-.)-2-(p-Isobutylphenyl)propionic acid; p-Isobutylhydratropic acid; Acide (isobutyl-4 phenyl)-2 propionique; Andran; Brufen; Buburone; Dolgit; Ebufac; Hydratropic acid, p-isobutyl-; Ibu-slo; Ibuprocin; IP-82; Liptan; Motrin; Nobfelon; Pantrop; R.D. 13621; Rebugen; U-18,573; 2-(p-Isobutylphenyl)propionic acid; 2-(4-Isobutylphenyl)propanoic acid; 4-Isobutylhydratropic acid; Adran; Anflagen; Artril 300; Bluton; Brufanic; Butylenin; Dolgin; Emodin; Epobron; Ibufen; Lamidon; Mynosedin; Napacetin; Nobfen; Nobgen; Nurofen; Roidenin; Benzeneacetic acid, α-methyl-4-(2-methylpropyl), (.+/-.)-; Advil; Haltran; Medipren; Midol 200; Nuprin; PediaProfen; Trendar; α-2-(p-Isobutylphenyl)propionic acid; Propanoic acid, 2-(4-isobutylphenyl); RD 13621; 4-Isobutylphenyl)-α-methylacetic acid; (RS)-Ibuprofen; p-Isobutyl-2-phenylpropionic acid; Burana; Butacortelone; Carol; Cobo; Optifen; Ostofen; Panafen; Proartinal; Proflex; Quadrax; Uprofen; Dibufen; Ibupril; Apsifen; α-Methyl-4-(2-methylpropyl)benzeneacetic acid; Advil Cold & Sinus (Salt/Mix); Children's Elixsure IB (Salt/Mix); Combunox (Salt/Mix); Motrin IB Gelcaps (Salt/Mix); Sine-Aid IB Caplets (Salt/Mix); (±) α-methyl-4-(isobutyl)phenylacetic acid (ibuprofen)
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Phase change data
Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: William E. Acree, Jr., James S. Chickos
Enthalpy of fusion
ΔfusH (kJ/mol) | Temperature (K) | Method | Reference | Comment |
---|---|---|---|---|
39.5 | 350.4 | DSC | Cilurzo, Alberti, et al., 2010 | |
27.94 | 347.6 | DSC | Hong, Hua, et al., 2010 | |
26.6 | 346.4 | DSC | Wassvik, Holmén, et al., 2006 | |
26.65 | 348. | N/A | Gracin and Rasmuson, 2002 | See also Xu, Sun, et al., 2004. |
25.7 | 350.9 | DSC | Li, Zell, et al., 1999 |
Mass spectrum (electron ionization)
Go To: Top, Phase change data, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | NIST Mass Spectrometry Data Center |
NIST MS number | 352144 |
Gas Chromatography
Go To: Top, Phase change data, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | DB-5 | 220. | 1622. | Phillips, Logan, et al., 1990 | 15. m/0.25 mm/0.2 μm, He |
Capillary | OV-101 | 200. | 1614. | Tarjan, Nyiredy, et al., 1989 | |
Packed | OV-101 | 200. | 1614. | Macek and Smolková-Keulemansová, 1985 | N2, Chromosorb W HP (100-120 mesh); Column length: 2. m |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 1594. | Perrigo, Peel, et al., 1985 | 15. m/0.32 mm/0.25 μm, He, 8. K/min, 280. C @ 5. min; Tstart: 120. C |
Capillary | DB-1 | 1594. | Perrigo, Ballantyne, et al., 1984 | 15. m/0.25 mm/0.25 μm, He, 8. K/min, 280. C @ 5. min; Tstart: 120. C |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | VF-5MS | 1630.2 | Tret'yakov, 2008 | 30. m/0.25 mm/0.25 μm, He; Program: Multi-step temperature program; T(initial)=60C; T(final)=270C |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 1585. | Anderson and Fuller, 1987 | 10. m/0.53 mm/2.65 μm, He, 5. K/min; Tstart: 130. C; Tend: 230. C |
Capillary | DB-1 | 1600. | Sharp, 1987 | 15. m/0.25 mm/0.25 μm, He, 130. C @ 1. min, 10. K/min, 290. C @ 10. min |
References
Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Cilurzo, Alberti, et al., 2010
Cilurzo, F.; Alberti, E.; Minghetti, P.; Gennari, C.G.M.; Casiraghi, A.; Montanari, L.,
Effect of drug chirality on the skin permeability of ibuprofen,
International Journal of Pharmaceutics, 2010, 386, 1-2, 71-76, https://doi.org/10.1016/j.ijpharm.2009.10.053
. [all data]
Hong, Hua, et al., 2010
Hong, Jindui; Hua, Dan; Wang, Xia; Wang, Hongtao; Li, Jun,
Solid-Liquid-Gas Equilibrium of the Ternaries Ibuprofen + Myristic Acid + CO 2 and Ibuprofen + Tripalmitin + CO 2,
J. Chem. Eng. Data, 2010, 55, 1, 297-302, https://doi.org/10.1021/je900342a
. [all data]
Wassvik, Holmén, et al., 2006
Wassvik, Carola M.; Holmén, Anders G.; Bergström, Christel A.S.; Zamora, Ismael; Artursson, Per,
Contribution of solid-state properties to the aqueous solubility of drugs,
European Journal of Pharmaceutical Sciences, 2006, 29, 3-4, 294-305, https://doi.org/10.1016/j.ejps.2006.05.013
. [all data]
Gracin and Rasmuson, 2002
Gracin, Sandra; Rasmuson, Åke C.,
Solubility of Phenylacetic Acid, p -Hydroxyphenylacetic Acid, p -Aminophenylacetic Acid, p -Hydroxybenzoic Acid, and Ibuprofen in Pure Solvents,
J. Chem. Eng. Data, 2002, 47, 6, 1379-1383, https://doi.org/10.1021/je0255170
. [all data]
Xu, Sun, et al., 2004
Xu, Fen; Sun, Li-Xian; Tan, Zhi-Cheng; Liang, Jian-Guo; Li, Rui-Lian,
Thermodynamic study of ibuprofen by adiabatic calorimetry and thermal analysis,
Thermochimica Acta, 2004, 412, 1-2, 33-57, https://doi.org/10.1016/j.tca.2003.08.021
. [all data]
Li, Zell, et al., 1999
Li, Z. Jane; Zell, Mark T.; Munson, Eric J.; Grant, David J.W.,
Characterization of racemic species of chiral drugs using thermal analysis, thermodynamic calculation, and structural studies,
J. Pharm. Sci., 1999, 88, 3, 337-346, https://doi.org/10.1021/js980205u
. [all data]
Phillips, Logan, et al., 1990
Phillips, A.M.; Logan, B.K.; Stafford, D.T.,
Further applications for capillary gas chromatography in routine quantitative toxicological analyses,
J. Hi. Res. Chromatogr., 1990, 13, 11, 754-758, https://doi.org/10.1002/jhrc.1240131106
. [all data]
Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M.,
Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography,
J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8
. [all data]
Macek and Smolková-Keulemansová, 1985
Macek, J.; Smolková-Keulemansová, E.,
Correlation of the chromatographic retention of some phenylacetic and phenylpropionic acid derivatives with molecular structure,
J. Chromatogr., 1985, 333, 309-317, https://doi.org/10.1016/S0021-9673(01)87361-1
. [all data]
Perrigo, Peel, et al., 1985
Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J.,
Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology.,
J. Chromatogr., 1985, 341, 81-88, https://doi.org/10.1016/S0378-4347(00)84011-6
. [all data]
Perrigo, Ballantyne, et al., 1984
Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W.,
Condierations in developing a data base for drugs on a DBI capillary column,
J. Can. Soc. Forensic Sci., 1984, 17, 2, 41-49, https://doi.org/10.1080/00085030.1984.10757360
. [all data]
Tret'yakov, 2008
Tret'yakov, K.V.,
Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2008. [all data]
Anderson and Fuller, 1987
Anderson, W.H.; Fuller, D.C.,
A simplified procedure for the isolation, characterization, and identification of weak acid and neutral drugs from whole blood,
J. Anal. Toxicol., 1987, 11, 5, 198-204, https://doi.org/10.1093/jat/11.5.198
. [all data]
Sharp, 1987
Sharp, M.E.,
A rapid screening procedure for acidic and neutral drugs in blood by high resolution gas chromatography,
J. Anal. Toxicol., 1987, 11, 1, 8-11, https://doi.org/10.1093/jat/11.1.8
. [all data]
Notes
Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, References
- Symbols used in this document:
ΔfusH Enthalpy of fusion - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.