Cyclobutane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Mass spectrum (electron ionization)

Go To: Top, Vibrational and/or electronic energy levels, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
NIST MS number 107

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Vibrational and/or electronic energy levels

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Takehiko Shimanouchi

Symmetry:   D2d     Symmetry Number σ = 4


 Sym.   No   Approximate   Selected Freq.  Infrared   Raman   Comments 
 Species   type of mode   Value   Rating   Value  Phase  Value  Phase

a1 1 CH2 s-str 2895  D  ia 2916 p liq. FR(2ν2,2ν13)
a1 1 CH2 s-str 2895  D  ia 2866 p liq. FR(2ν2,2ν13)
a1 2 CH2 scis 1443  C  ia 1443 p liq. SF13)
a1 3 Ring str 1001  C  ia 1001 p liq. SF14)
a1 4 CH2 a-str 2975  E  ia CF
a1 5 CH2 rock 741  C  ia 741 dp liq.
a1 6 Ring puck 197  C  ia 197 liq. CF
a2 7 CH2 wag 1260  E  ia  ia CF
a2 8 CH2 twist 1257  E  ia  ia CF
b1 9 CH2 wag 1219  C  ia 1219 dp liq.
b1 10 Ring deform 926  C  ia 926 dp liq.
b1 11 CH2 twist 1222  E  ia CF
b2 12 CH2 s-str 2893  E CF
b2 13 CH2 scis 1443  C 1443 dp liq. SF2)
b2 14 Ring deform 1001  D 1001 p liq. SF3)
b2 15 CH2 a-str 2987  C 2987 S gas
b2 16 CH2 rock 627  C 627 S gas
e 17 CH2 a-str 2952  C 2952 liq.
e 18 CH2 twist 1223  C 1223 W gas
e 19 CH2 rock 749  C 749 W gas
e 20 CH2 s-str 2887  D 2897 S gas
e 20 CH2 s-str 2887  D 2878 S gas
e 21 CH2 scis 1447  C 1447 S gas
e 22 CH2 wag 1257  C 1257 S gas
e 23 Ring deform 898  C 898 S gas

Source: Shimanouchi, 1972

Notes

SStrong
WWeak
iaInactive
pPolarized
dpDepolarized
FRFermi resonance with an overtone or a combination tone indicated in the parentheses.
CFCalculated frequency
SFCalculation shows that the frequency approximately equals that of the vibration indicated in the parentheses.
C3~6 cm-1 uncertainty
D6~15 cm-1 uncertainty
E15~30 cm-1 uncertainty

Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), Vibrational and/or electronic energy levels, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSqualane27.462.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm
PackedSqualane49.464.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm
PackedSqualane67.465.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm
PackedSqualane86.467.Hively and Hinton, 1968He, Chromosorb P; Column length: 15. m; Column diameter: 0.25 mm

References

Go To: Top, Mass spectrum (electron ionization), Vibrational and/or electronic energy levels, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Shimanouchi, 1972
Shimanouchi, T., Tables of Molecular Vibrational Frequencies Consolidated Volume I, National Bureau of Standards, 1972, 1-160. [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]


Notes