1,1-Dichloro-1-fluoroethane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos

Quantity Value Units Method Reference Comment
Tboil305.KN/APCR Inc., 1990BS
Tboil305.2KN/AWeast and Grasselli, 1989BS
Tboil305.15KN/AHenne and Plueddeman, 1943Uncertainty assigned by TRC = 0.4 K; TRC
Tboil304.9KN/AHenne and Renoll, 1936Uncertainty assigned by TRC = 0.5 K; TRC
Quantity Value Units Method Reference Comment
Tfus169.65KN/AHenne and Plueddeman, 1943Uncertainty assigned by TRC = 0.5 K; TRC
Quantity Value Units Method Reference Comment
Tc477.5KN/ADuarte-Garza, Hwang, et al., 1997Uncertainty assigned by TRC = 0.5 K; by visual disappearance of meniscus; TRC
Tc477.3KN/AChae, Schmidt, et al., 1990Uncertainty assigned by TRC = 0.5 K; by extrapolation to equality of L and G refr. index; TRC
Quantity Value Units Method Reference Comment
Pc41.94barN/ADuarte-Garza, Hwang, et al., 1997Uncertainty assigned by TRC = 0.05 bar; by extrapolation of vapor pressure to Tc; TRC
Quantity Value Units Method Reference Comment
ρc4.152mol/lN/ADuarte-Garza, Hwang, et al., 1997Uncertainty assigned by TRC = 0.02 mol/l; extrapolation to Tc with law of rectilinear diameters; TRC
ρc3.94mol/lN/AChae, Schmidt, et al., 1990Uncertainty assigned by TRC = 0.07 mol/l; derived from obs L and G refractive index; TRC

Enthalpy of vaporization

ΔvapH (kJ/mol) Temperature (K) Method Reference Comment
28.7265.N/ADuarte-Garza, Hwang, et al., 1997Based on data from 250. to 450. K.; AC
27.8285.EBWeber, 1992Based on data from 270. to 312. K.; AC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Mass spectrum (electron ionization)

Go To: Top, Phase change data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin T.J. Bruno, Cent. Chem. Technol., NIST, Boulder, CO 80303, USA
NIST MS number 142369

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Phase change data, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-101541.Zenkevich, 200525. m/0.20 mm/0.10 μm, N2/He, 6. K/min; Tstart: 50. C; Tend: 250. C

References

Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

PCR Inc., 1990
PCR Inc., Research Chemicals Catalog 1990-1991, PCR Inc., Gainesville, FL, 1990, 1. [all data]

Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]

Henne and Plueddeman, 1943
Henne, A.L.; Plueddeman, E.P., The Addition of Hydrogen Fluoride to Halo-olefins, J. Am. Chem. Soc., 1943, 65, 1271. [all data]

Henne and Renoll, 1936
Henne, A.L.; Renoll, M.W., J. Am. Chem. Soc., 1936, 58, 889. [all data]

Duarte-Garza, Hwang, et al., 1997
Duarte-Garza, Horacio A.; Hwang, Chih-An; Kellerman, Scott A.; Miller, Reid C.; Hall, Kenneth R.; Holste, James C.; Marsh, Kenneth N.; Gammon, Bruce E., Vapor Pressure, Vapor Density, and Liquid Density for 1,1-Dichloro-1-fluoroethane (R-141b), J. Chem. Eng. Data, 1997, 42, 3, 497-501, https://doi.org/10.1021/je9603584 . [all data]

Chae, Schmidt, et al., 1990
Chae, H.B.; Schmidt, J.W.; Moldover, M.R., Alternative refrigerants R123a, R134, R141b, R142b, and R152a: critical temperature, refractive index, surface tension, and estimates of liquid, vapor, and critical densities, J. Phys. Chem., 1990, 94, 8840-5. [all data]

Weber, 1992
Weber, L.A., Ebulliometric measurement of the vapor pressures of R123 and R141b, Fluid Phase Equilibria, 1992, 80, 141-148, https://doi.org/10.1016/0378-3812(92)87062-R . [all data]

Zenkevich, 2005
Zenkevich, I.G., Experimentally measured retention indices., 2005. [all data]


Notes

Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, References