Hydrogen peroxide

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas phase thermochemistry data

Go To: Top, Phase change data, IR Spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Quantity Value Units Method Reference Comment
Δfgas-136.11kJ/molReviewChase, 1998Data last reviewed in December, 1960
Quantity Value Units Method Reference Comment
gas,1 bar232.95J/mol*KReviewChase, 1998Data last reviewed in December, 1960

Gas Phase Heat Capacity (Shomate Equation)

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

View table.

Temperature (K) 298. to 1500.
A 34.25667
B 55.18445
C -35.15443
D 9.087440
E -0.422157
F -149.9098
G 257.0604
H -136.1064
ReferenceChase, 1998
Comment Data last reviewed in December, 1960

Phase change data

Go To: Top, Gas phase thermochemistry data, IR Spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos

Quantity Value Units Method Reference Comment
Tfus272.26KN/ACuthbertson, Matheson, et al., 1928Uncertainty assigned by TRC = 0.3 K; TRC
Quantity Value Units Method Reference Comment
Tc728.KN/ANikitin, Pavlov, et al., 1995Uncertainty assigned by TRC = 15. K; by extrapolation of obs. Tc for aqueous solns, with pulse heating method to pure H2O2; TRC
Quantity Value Units Method Reference Comment
Pc220.00barN/ANikitin, Pavlov, et al., 1995Uncertainty assigned by TRC = 20.00 bar; by extrapolation of obs. Pc for aqueous solns. with pulse heating method to pure H2O2; TRC

Enthalpy of vaporization

ΔvapH (kJ/mol) Temperature (K) Reference Comment
48.5320.Maass and Hiebert, 1924Based on data from 277. to 363. K.; AC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


IR Spectrum

Go To: Top, Gas phase thermochemistry data, Phase change data, References, Notes

Data compiled by: Tanya L. Myers, Russell G. Tonkyn, Ashley M. Oeck, Tyler O. Danby, John S. Loring, Matthew S. Taubman, Stephen W. Sharpe, Jerome C. Birnbaum, and Timothy J. Johnson


References

Go To: Top, Gas phase thermochemistry data, Phase change data, IR Spectrum, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]

Cuthbertson, Matheson, et al., 1928
Cuthbertson, A.C.; Matheson, G.L.; Maass, O., The Freezing Point and Density of Pure Hydrogen Peroxide, J. Am. Chem. Soc., 1928, 50, 1120. [all data]

Nikitin, Pavlov, et al., 1995
Nikitin, E.D.; Pavlov, P.A.; Popov, A.P.; Nikitina, H.E., Critical properties of hydrogen peroxide determined from direct measurements, J. Chem. Thermodyn., 1995, 27, 945-52. [all data]

Maass and Hiebert, 1924
Maass, O.; Hiebert, P.G., THE PROPERTIES OF PURE HYDROGEN PEROXIDE. V. VAPOR PRESSURE, J. Am. Chem. Soc., 1924, 46, 12, 2693-2700, https://doi.org/10.1021/ja01677a012 . [all data]


Notes

Go To: Top, Gas phase thermochemistry data, Phase change data, IR Spectrum, References