1,3,5-Triazine
- Formula: C3H3N3
- Molecular weight: 81.0760
- IUPAC Standard InChIKey: JIHQDMXYYFUGFV-UHFFFAOYSA-N
- CAS Registry Number: 290-87-9
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: s-Triazine; Cyanidine; Vedita 250; s-Triazine-(1,3,5); sym-Triazine
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Gas phase thermochemistry data
Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
ΔfH°gas | 225.87 ± 0.89 | kJ/mol | Ccr | Bystrom, 1982 | |
ΔfH°gas | 224.7 ± 4.6 | kJ/mol | Cm | Iniguez, Lopez, et al., 1982 |
Condensed phase thermochemistry data
Go To: Top, Gas phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
ALS - Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
DH - Eugene S. Domalski and Elizabeth D. Hearing
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
ΔcH°liquid | -1782.6 ± 0.92 | kJ/mol | Ccb | Johnson and Prosen, 1985 | Private communication; ALS |
Quantity | Value | Units | Method | Reference | Comment |
ΔfH°solid | 171.69 ± 0.77 | kJ/mol | Ccr | Bystrom, 1982 | ALS |
Quantity | Value | Units | Method | Reference | Comment |
ΔcH°solid | -1780.96 ± 0.67 | kJ/mol | Ccr | Bystrom, 1982 | ALS |
Quantity | Value | Units | Method | Reference | Comment |
S°solid,1 bar | 125.97 | J/mol*K | N/A | van Bommel, van Miltenburg, et al., 1988 | DH |
Constant pressure heat capacity of solid
Cp,solid (J/mol*K) | Temperature (K) | Reference | Comment |
---|---|---|---|
95.57 | 298.15 | van Bommel, van Miltenburg, et al., 1988 | T = 10 to 340 K.; DH |
95.6 | 298.15 | Briels and van Miltenburg, 1979 | T = 160 to 382 K.; DH |
IR Spectrum
Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Gas Phase Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Owner | NIST Standard Reference Data Program Collection (C) 2018 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | NIST Mass Spectrometry Data Center |
State | gas |
Instrument | HP-GC/MS/IRD |
Mass spectrum (electron ionization)
Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, IR Spectrum, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | NIST Mass Spectrometry Data Center, 1990. |
NIST MS number | 118737 |
Gas Chromatography
Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | OV-101 | 110. | 663. | Zhuravleva, 2000 | 50. m/0.3 mm/0.4 μm, He |
Capillary | OV-101 | 110. | 663. | Golovnya, Kuz'menko, et al., 1999 | 50. m/0.3 mm/0.4 μm, He |
References
Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Bystrom, 1982
Bystrom, K.,
The stabilization energy of 1,3,5-triazine derived from measurements of the enthalpies of combustion and sublimation,
J. Chem. Thermodyn., 1982, 14, 865-870. [all data]
Iniguez, Lopez, et al., 1982
Iniguez, J.C.; Lopez, M.E.; McEachern, D.M.,
Vapor pressure and sublimation enthalpy of s-triazine,
Rev. Soc. Quim. Mex., 1982, 26, 122-124. [all data]
Johnson and Prosen, 1985
Johnson, W.H.; Prosen, E.J.,
Determination of the enthalpies of combustion and formation of substituted triazines in an adiabatic rotating bomb calorimeter,
J. Res. NBS, 1985, 90, 295-303. [all data]
van Bommel, van Miltenburg, et al., 1988
van Bommel, M.J.; van Miltenburg, J.C.; Schuijff, A.,
Heat-capacity measurements and thermodynamic functions of 1,3,5-triazine and 1,3,5-trioxane,
J. Chem. Thermodynam., 1988, 20, 397-403. [all data]
Briels and van Miltenburg, 1979
Briels, W.J.; van Miltenburg, J.C.,
s-Triazine: heat capacities between 130 and 380 K, the solid state transition, and the enthalpy of melting,
J. Chem. Phys., 1979, 70, 1064-1066. [all data]
Zhuravleva, 2000
Zhuravleva, I.L.,
Evaluation of the polarity and boiling points of nitrogen-containing heterocyclic compounds by gas chromatography,
Russ. Chem. Bull. (Engl. Transl.), 2000, 49, 2, 325-328, https://doi.org/10.1007/BF02494682
. [all data]
Golovnya, Kuz'menko, et al., 1999
Golovnya, R.V.; Kuz'menko, T.E.; Zhuravleva, I.L.,
Gas chromatographic indicator of the ability of five- and six-membered heterocyclic nitrogen-containing compounds for self-association in pure liquids,
Russ. Chem. Bull. (Engl. Transl.), 1999, 48, 4, 726-729, https://doi.org/10.1007/BF02496256
. [all data]
Notes
Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References
- Symbols used in this document:
Cp,solid Constant pressure heat capacity of solid S°solid,1 bar Entropy of solid at standard conditions (1 bar) ΔcH°liquid Enthalpy of combustion of liquid at standard conditions ΔcH°solid Enthalpy of combustion of solid at standard conditions ΔfH°gas Enthalpy of formation of gas at standard conditions ΔfH°solid Enthalpy of formation of solid at standard conditions - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.