Thianthrene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos
ALS - Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
DH - Eugene S. Domalski and Elizabeth D. Hearing

Quantity Value Units Method Reference Comment
Tboil639.2KN/AWeast and Grasselli, 1989BS
Quantity Value Units Method Reference Comment
Tfus429.KN/AMayer, Howell, et al., 1990Uncertainty assigned by TRC = 1. K; TRC
Tfus429.85KN/ACullinane and Rees, 1940Uncertainty assigned by TRC = 0.5 K; TRC
Quantity Value Units Method Reference Comment
Ttriple429.570KN/ASteele, Chirico, et al., 1993Uncertainty assigned by TRC = 0.002 K; TRC
Ttriple428.43KN/ASabbah and El Watik, 1989Uncertainty assigned by TRC = 0.38 K; TRC
Quantity Value Units Method Reference Comment
Δsub99.39 ± 0.56kJ/molCSabbah and El Watik, 1989, 2ALS
Δsub99.4 ± 0.6kJ/molN/ASabbah and El Watik, 1989, 2AC

Reduced pressure boiling point

Tboil (K) Pressure (bar) Reference Comment
477.20.015Weast and Grasselli, 1989BS

Enthalpy of vaporization

ΔvapH (kJ/mol) Temperature (K) Method Reference Comment
71.2444.N/ADykyj, Svoboda, et al., 1999Based on data from 429. to 460. K.; AC
68.4475.N/ADykyj, Svoboda, et al., 1999Based on data from 460. to 539. K.; AC
72.7440.EB,IPSteele, Chirico, et al., 1993, 2Based on data from 395. to 639. K.; AC
69.9480.EB,IPSteele, Chirico, et al., 1993, 2Based on data from 395. to 639. K.; AC
67.2520.EB,IPSteele, Chirico, et al., 1993, 2Based on data from 395. to 639. K.; AC
64.5560.EB,IPSteele, Chirico, et al., 1993, 2Based on data from 395. to 639. K.; AC
61.7600.EB,IPSteele, Chirico, et al., 1993, 2Based on data from 395. to 639. K.; AC
69.1465.N/ASivaraman and Kobayashi, 1983Based on data from 430. to 593. K.; AC
68.7515.N/ASivaraman and Kobayashi, 1983Based on data from 430. to 593. K.; AC
71.1438.GSEdwards and Prausnitz, 1981Based on data from 428. to 448. K.; AC

Enthalpy of sublimation

ΔsubH (kJ/mol) Temperature (K) Method Reference Comment
103.6 ± 0.4350.IPSteele, Chirico, et al., 1993, 2AC
98.6 ± 0.5353.N/ASabbah and El Watik, 1989, 2Based on data from 338. to 368. K.; AC
98.0393.GSEdwards and Prausnitz, 1981Based on data from 358. to 428. K.; AC
97.5 ± 6.3353.HSASandman, Epstein, et al., 1979Based on data from 338. to 368. K.; AC

Enthalpy of fusion

ΔfusH (kJ/mol) Temperature (K) Reference Comment
27.5551429.576Steele, Chirico, et al., 1993, 2DH
27.55429.6Steele, Chirico, et al., 1993, 2AC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Mass spectrum (electron ionization)

Go To: Top, Phase change data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin D.HENNEBERG, MAX-PLANCK INSTITUTE, MULHEIM, WEST GERMANY
NIST MS number 63109

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Phase change data, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
PackedSE-301901.Ramsey, Lee, et al., 1980He, Chromosorb G HP (80-100 mesh); Column length: 1.5 m; Program: not specified

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryUltra-11883.Okumura, 199125. m/0.32 mm/0.25 μm, He, 3. K/min; Tstart: 80. C; Tend: 260. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone1909.Zenkevich, 1994Program: not specified
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1901.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified
OtherMethyl Silicone1901.Ardrey and Moffat, 1981Program: not specified

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-5327.9Durlak, Biswas, et al., 199830. m/0.25 mm/0.25 μm, 15. K/min; Tstart: 50. C; Tend: 300. C
CapillaryOV-101328.58Blanco, Blanco, et al., 1989H2, 4. K/min; Column length: 25. m; Column diameter: 0.22 mm; Tstart: 50. C; Tend: 300. C
CapillarySE-52330.13Lee, Vassilaros, et al., 197912. m/0.3 mm/0.34 μm, He, 2. K/min; Tstart: 50. C; Tend: 250. C

References

Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]

Mayer, Howell, et al., 1990
Mayer, M.M.; Howell, W.J.; Tomasko, D.L.; Eckert, C.A., Solid-solid Equilibria in the Systems Thianthrene + Phenanthrene, Salicylic Acid + Phenanthrene, and 3-Hydroxybenzoic Acid + Phenanthrene, J. Chem. Eng. Data, 1990, 35, 446. [all data]

Cullinane and Rees, 1940
Cullinane, N.M.; Rees, W.T., Isomorphous relationships of some organic compounds of analogous constitution, Trans. Faraday Soc., 1940, 36, 507. [all data]

Steele, Chirico, et al., 1993
Steele, W.V.; Chirico, R.D.; Knipmeyer, S.E.; Nguyen, A., The thermodynamic properties of thianthrene and phenoxathiin, J. Chem. Thermodyn., 1993, 25, 965-92. [all data]

Sabbah and El Watik, 1989
Sabbah, R.; El Watik, L., Thermodynamic study of the thianthrene molecule, Thermochim. Acta, 1989, 138, 241. [all data]

Sabbah and El Watik, 1989, 2
Sabbah, R.; El Watik, L., Etude thermodynamique de la molecule de thianthrene, Thermochim. Acta, 1989, 138, 241-247. [all data]

Dykyj, Svoboda, et al., 1999
Dykyj, J.; Svoboda, J.; Wilhoit, R.C.; Frenkel, M.L.; Hall, K.R., Vapor Pressure of Chemicals: Part A. Vapor Pressure and Antoine Constants for Hydrocarbons and Sulfur, Selenium, Tellurium and Hydrogen Containing Organic Compounds, Springer, Berlin, 1999, 373. [all data]

Steele, Chirico, et al., 1993, 2
Steele, W.V.; Chirico, R.D.; Knipmeyer, S.E.; Nguyen, A., The thermodynamic properties of thianthrene and phenoxathiin, J. Chem. Thermodyn., 1993, 25, 965-992. [all data]

Sivaraman and Kobayashi, 1983
Sivaraman, Alwarappa; Kobayashi, Riki, Vapor pressures and enthalpies of vaporization of thianthrene, acridine, and 9-methylanthracene at elevated temperatures, The Journal of Chemical Thermodynamics, 1983, 15, 12, 1127-1135, https://doi.org/10.1016/0021-9614(83)90003-4 . [all data]

Edwards and Prausnitz, 1981
Edwards, D.R.; Prausnitz, J.M., Vapor pressures of some sulfur-containing, coal-related compounds, J. Chem. Eng. Data, 1981, 26, 2, 121-124, https://doi.org/10.1021/je00024a005 . [all data]

Sandman, Epstein, et al., 1979
Sandman, D.J.; Epstein, A.J.; Chickos, J.S.; Ketchum, J.; Fu, J.S.; Scheraga, H.A., Crystal lattice and polarization energy of tetrathiafulvalene, J. Chem. Phys., 1979, 70, 1, 305, https://doi.org/10.1063/1.437191 . [all data]

Ramsey, Lee, et al., 1980
Ramsey, J.D.; Lee, T.D.; Osselton, M.D.; Moffat, A.C., Gas-liquid chromatographic retention indices of 296 non-drug substances on SE-30 or OV-1 likely to be encountered in toxicological analyses, J. Chromatogr., 1980, 184, 2, 185-206, https://doi.org/10.1016/S0021-9673(00)85641-1 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]

Zenkevich, 1994
Zenkevich, I.G., Contemporary State of Informational Maintenance for Gas Chromatographic Identification of Chlorinated Polycyclic Aromatic Compounds, Zh. Ecol. Khim., 1994, 3, 2, 111-119. [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]

Ardrey and Moffat, 1981
Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 1981, 220, 3, 195-252, https://doi.org/10.1016/S0021-9673(00)81925-1 . [all data]

Durlak, Biswas, et al., 1998
Durlak, S.K.; Biswas, P.; Shi, J.; Bernhard, M.J., Characterization of polycyclic aromatic hydrocarbon particulate and gaseous emissions from polystyrene combustion, Environ. Sci. Technol., 1998, 32, 15, 2301-2307, https://doi.org/10.1021/es9709031 . [all data]

Blanco, Blanco, et al., 1989
Blanco, C.G.; Blanco, J.; Bermejo, J.; Guillen, M.D., Capillary gas chromatography of some polycyclic aromatic compounds on several stationary phases, J. Chromatogr., 1989, 465, 3, 378-385, https://doi.org/10.1016/S0021-9673(01)92675-5 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]


Notes

Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, References