1,3-Hexanediol, 2-ethyl-
- Formula: C8H18O2
- Molecular weight: 146.2273
- IUPAC Standard InChIKey: RWLALWYNXFYRGW-UHFFFAOYSA-N
- CAS Registry Number: 94-96-2
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Carbide 6-12; Ethohexadiol; Octylene glycol; Repellent 612; Rutgers 612; 2-Ethyl-1,3-hexandiol; 2-Ethyl-1,3-hexanediol; 2-Ethyl-1,3-hexylene glycol; 6-12; 6-12-Insect repellent; 2-Ethylhexane-1,3-diol; Compound 6-12, insect repellent; Ethyl hexanediol; Ethyl hexylene glycol; ENT 375; 2-Ethyl-3-propyl-1,3-propanediol; 2-Ethylhexanediol-1,3; 3-Hydroxymethyl-n-heptan-4-ol; 2-Ethylhexanediol; EH diol; EHD; Ethyl-1,3-hexane diol-2; NSC 3881; Diol-Kyowa 8
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Phase change data
Go To: Top, Henry's Law data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos
Quantity | Value | Units | Method | Reference | Comment |
---|---|---|---|---|---|
Tboil | 517.2 | K | N/A | Weast and Grasselli, 1989 | BS |
Tboil | 516.25 | K | N/A | Mellan, 1962 | Uncertainty assigned by TRC = 1. K; TRC |
Quantity | Value | Units | Method | Reference | Comment |
ΔvapH° | 19.0 | kcal/mol | N/A | Blaine and Levy, 1974 | Based on data from 331. to 413. K. See also Verevkin, 2007.; AC |
Henry's Law data
Go To: Top, Phase change data, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Rolf Sander
Henry's Law constant (water solution)
kH(T) = k°H exp(d(ln(kH))/d(1/T) ((1/T) - 1/(298.15 K)))
k°H = Henry's law constant for solubility in water at 298.15 K (mol/(kg*bar))
d(ln(kH))/d(1/T) = Temperature dependence constant (K)
k°H (mol/(kg*bar)) | d(ln(kH))/d(1/T) (K) | Method | Reference | Comment |
---|---|---|---|---|
2.0×10+6 | E | N/A | Value obtained by missing citation using the group contribution method. |
References
Go To: Top, Phase change data, Henry's Law data, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]
Mellan, 1962
Mellan, I.,
Polyhydric Alcohols, Spartan Books: Washington, DC, 1962. [all data]
Blaine and Levy, 1974
Blaine, Roger L.; Levy, Paul F.,
The Use of Thermal Evolution Analysis (TEA) for the Determination of Vapor Pressure of Agricultural Chemicals, 1974, 185-198, https://doi.org/10.1007/978-1-4757-4509-215
. [all data]
Verevkin, 2007
Verevkin, Sergey P.,
Vapor Pressures and Enthalpies of Vaporization of a Series of the 1,3-Alkanediols,
J. Chem. Eng. Data, 2007, 52, 1, 301-308, https://doi.org/10.1021/je060419q
. [all data]
Notes
Go To: Top, Phase change data, Henry's Law data, References
- Symbols used in this document:
Tboil Boiling point d(ln(kH))/d(1/T) Temperature dependence parameter for Henry's Law constant k°H Henry's Law constant at 298.15K ΔvapH° Enthalpy of vaporization at standard conditions - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.