Cyclohexane, 1,2,3,4,5-pentamethyl


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SE-30SE-30SE-30Squalane
Column length (m) 6.16.16.16.150.
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm) 3.183.183.183.180.2
Phase thickness (μm)      
Temperature (C) 130.140.150.160.100.
I 1073.1080.1085.1089.1093.
ReferenceMitra, Mohan, et al., 1974Mitra, Mohan, et al., 1974Mitra, Mohan, et al., 1974Mitra, Mohan, et al., 1974Mitra, Mohan, et al., 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)    
Carrier gas    
Substrate    
Column diameter (mm)    
Phase thickness (μm)    
Temperature (C) 130.130.130.
I 1050.1072.1105.
ReferenceAntheaume and Guiochon, 1965Antheaume and Guiochon, 1965Antheaume and Guiochon, 1965
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Mitra, Mohan, et al., 1974
Mitra, G.D.; Mohan, G.; Sinha, A., Gas chromatographic analysis of complex hydrocarbon mixtures, J. Chromatogr. A, 1974, 91, 633-648, https://doi.org/10.1016/S0021-9673(01)97944-0 . [all data]

Antheaume and Guiochon, 1965
Antheaume, J.; Guiochon, G., Application de la chromatographie en phase gazeuse à l'étude de la composition des fractions moyennes d'un brut pétrolier, Bull. Soc. Chim. Fr., 1965, 2, 298-307. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References