15-Methylpentatriacontane
- Formula: C36H74
- Molecular weight: 506.9728
- IUPAC Standard InChIKey: CUYUHFDLJSUYHY-UHFFFAOYSA-N
- Chemical structure:
This structure is also available as a 2d Mol file - Species with the same structure:
- Other names: Pentatriacontane, 15-methyl
- Information on this page:
- Options:
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5MS | 3530. | Steiner, Steidle, et al., 2005 | 30. m/0.32 mm/0.25 μm, He, 2. K/min; Tstart: 150. C; Tend: 300. C |
Capillary | Ultra-1 | 3526. | Nelson, Adams, et al., 2003 | 150. C @ 4. min, 4. K/min, 320. C @ 30. min; Column length: 12. m; Column diameter: 0.2 mm |
Capillary | HT-5 | 3523. | Goh S.H., Ooi K.E., et al., 1993 | 25. m/0.53 mm/0.22 μm, N2, 15. K/min, 320. C @ 20. min; Tstart: 150. C |
Capillary | HT-5 | 3524. | Goh S.H., Ooi K.E., et al., 1993 | 25. m/0.53 mm/0.22 μm, N2, 15. K/min, 320. C @ 20. min; Tstart: 150. C |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 3535. | Bernier, Carlson, et al., 1998 | 30. m/0.32 mm/0.25 μm; Program: 60C (2min) => 10C/min => 220C => 3C/min => 310C |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Ultra-1 | 3526. | Nelson and Charlet, 2003 | He, 4. K/min; Column length: 12.5 m; Column diameter: 0.2 mm; Tstart: 150. C; Tend: 320. C |
Capillary | BP-1 | 3527. | Lockey and Oraha, 1990 | 12. m/0.22 mm/0.25 μm, Helium, 2. K/min; Tstart: 100. C; Tend: 300. C |
Packed | OV-101 | 3530. | Nelson, de Renobales, et al., 1989 | Helium, Gas-Chrom Q (100-120 mesh), 3. K/min, 320. C @ 25. min; Column length: 3. m; Tstart: 150. C |
Packed | Dexsil 300 | 3533. | Lockey, 1976 | Nitrogen, Chromosorb W (80-100 mesh), 3.3 K/min; Column length: 2. m; Tstart: 80. C; Tend: 340. C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 3535. | Carlson, Geden, et al., 1999 | 30. m/0.32 mm/0.25 μm, He; Program: 60C (2min) => 10C/min => 220C => 3C/min => 310C (12 - 42 min) |
Capillary | CP Sil 5 CB | 3529. | Kenig, Sinninghe Damsté, et al., 1995 | 25. m/0.32 mm/0.2 μm, He; Program: 50C => 20C/min => 130C => 4C/min => 300C (20min) |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Steiner, Steidle, et al., 2005
Steiner, S.; Steidle, J.L.M.; Ruther, J.,
Female sex pheromone in immature insect males - a case of pre-emergence chemical mimicry?,
Behavioral Ecology and Sociobiology, 2005, 58, 2, 111-120, https://doi.org/10.1007/s00265-005-0930-x
. [all data]
Nelson, Adams, et al., 2003
Nelson, D.R.; Adams, T.S.; Fatland, C.L.,
Hydrocarbons in the surface wax of eggs and adults of the Colorado potato beetle, Leptinotarsa decemlineata,
Comp. Biochem. Physiol. B: Comp. Biochem., 2003, 134, 3, 447-466, https://doi.org/10.1016/S1096-4959(02)00262-2
. [all data]
Goh S.H., Ooi K.E., et al., 1993
Goh S.H.; Ooi K.E.; Chuah C.H.; Yong H.S.; Khoo S.G.; Ong S.H.,
Cuticular hydrocarbons from two species of Malaysian Bactrocera fruit flies,
Biochem. Syst. Ecol., 1993, 21, 2, 215-226, https://doi.org/10.1016/0305-1978(93)90039-T
. [all data]
Bernier, Carlson, et al., 1998
Bernier, U.R.; Carlson, D.A.; Geden, C.J.,
Gas chromatography/mass spectrometry analysis of the cuticular hydrocarbons from parasitic wasps of the genus Muscidifurax,
J. Am. Soc. Mass Spectrom., 1998, 9, 4, 320-332, https://doi.org/10.1016/S1044-0305(97)00288-2
. [all data]
Nelson and Charlet, 2003
Nelson, D.R.; Charlet, L.D.,
Cuticular hydrocarbons of the sunflower beetle,Zygogramma exclamationis,
Comp. Biochem. Physiol. B: Comp. Biochem., 2003, 135, 2, 273-284, https://doi.org/10.1016/S1096-4959(03)00080-0
. [all data]
Lockey and Oraha, 1990
Lockey, K.H.; Oraha, V.S.,
Cuticular lipids of adult Locusta Migratoria Migratoriodes (R and F), Schstocerca Gregaria (Forskal) (Acrididae) and other orthopteran species - II. Hydrocarbons,
Comp. Biochem. Physiol., 1990, 95B, 4, 721-744. [all data]
Nelson, de Renobales, et al., 1989
Nelson, D.R.; de Renobales, M.; Dwyer, L.A.; Zamboni, A.C.; Fatland, C.L.; Blomquist, G.J.,
Novel very long-chain methyl branched alcohols and their esters, and methyl branched alkanes in pupae of the gabbage looper, Trichoplusa ni (Hubner),
Insect Biochem., 1989, 19, 2, 197-208, https://doi.org/10.1016/0020-1790(89)90092-9
. [all data]
Lockey, 1976
Lockey, K.H.,
Cuticular hydrocarbons of Locusta, Schistocerca, and Periplaneta, and their role in waterproofing,
Insect Biochem., 1976, 6, 5, 457-472, https://doi.org/10.1016/0020-1790(76)90068-8
. [all data]
Carlson, Geden, et al., 1999
Carlson, D.A.; Geden, C.J.; Bernier, U.R.,
Identification of pupal exiviae of Nasania vitripennis and Muscidifurax raptorellus parasitoids using cuticular hydrocarbons,
Biol. Control, 1999, 15, 2, 97-106, https://doi.org/10.1006/bcon.1999.0708
. [all data]
Kenig, Sinninghe Damsté, et al., 1995
Kenig, F.; Sinninghe Damsté, J.S.; Kock-van Dalen, A.C.; Rijpstra, W.I.C.; Huc, A.Y.; de Leeuw, J.W.,
Occurrence and origin of mono-, di-, and trimethylalkanes in modern and holocene cyanobacterial mats from Abu Dhabi, United Arab Emirates,
Geochim. Cosmochim. Acta, 1995, 59, 14, 2999-3015, https://doi.org/10.1016/0016-7037(95)00190-5
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.