β-Lactose, TMS


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillary
Active phase SE-54OV-101
Column length (m) 40.45.
Carrier gas N2 
Substrate   
Column diameter (mm) 0.180.25
Phase thickness (μm)   
Temperature (C) 280.272.
I 2833.2790.
ReferenceGarcía-Raso, Páez, et al., 1992Adam and Jennings, 1975
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

García-Raso, Páez, et al., 1992
García-Raso, A.; Páez, M.I.; Martínez-Castro, I.; Sanz, J.; Calvo, M.M., Gas chromatographic retention of carbohydrate trimethylsilyl ethers. IV. Disaccharides, J. Chromatogr., 1992, 607, 2, 221-225, https://doi.org/10.1016/0021-9673(92)87079-N . [all data]

Adam and Jennings, 1975
Adam, S.; Jennings, W.G., Gas chromatographic separation of silylated derivatives of disaccharide mixtures on open tubular glass capillary columns, J. Chromatogr., 1975, 115, 1, 218-221, https://doi.org/10.1016/S0021-9673(00)89035-4 . [all data]


Notes