(Diisopropylamino)ethanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, IR Spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Quantity Value Units Method Reference Comment
Tboil463.2KN/AWeast and Grasselli, 1989BS
Quantity Value Units Method Reference Comment
Tfus233.9KN/AAnonymous, 1952Uncertainty assigned by TRC = 0.6 K; TRC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


IR Spectrum

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Tanya L. Myers, Russell G. Tonkyn, Ashley M. Oeck, Tyler O. Danby, John S. Loring, Matthew S. Taubman, Stephen W. Sharpe, Jerome C. Birnbaum, and Timothy J. Johnson

Condensed Phase Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

IR spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Detailed documentation for this spectrum is available.

Owner Public domain
Origin Pacific Northwest National Laboratory Under IARPA Contract
Date March 2017
State liquid
Instrument Bruker Tensor 27 FTIR
Instrument resolution 2.0 cm-1
IR source Silicon carbide glow bar
Aperture 3 mm
Beam splitter Broadband potassium bromide (KBr)
Detector DLTGS at room temperature
Scanner velocity 10 kHz
Phase correction Mertz
Interferogram zero fill 4x
Spectral interval after zero fill 0.4823 cm-1
Spectral range 7800 to 400 cm-1 (1.282 to 25 microns)
Resolution 0.4821395
Apodization Norton-Beer, Medium
Folding limits 15802 to 0 cm-1
Number of interferograms averaged per single channel spectrum 128

References

Go To: Top, Phase change data, IR Spectrum, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]

Anonymous, 1952
Anonymous, R., , Physical Properties of Chemical Substances, Dow Chemical Co., 1952. [all data]


Notes

Go To: Top, Phase change data, IR Spectrum, References