Benzene, 1-bromo-2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


IR Spectrum

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compiled by: Coblentz Society, Inc.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director


Mass spectrum (electron ionization)

Go To: Top, IR Spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin NIST Mass Spectrometry Data Center, 1998.
NIST MS number 291336

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryDB-5110.1053.73Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillaryDB-570.1032.58Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillaryDB-590.1042.66Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-11016.9Gautzsch and Zinn, 19968. K/min; Tstart: 35. C; Tend: 300. C
CapillaryDB-51022.72Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-51027.31Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-51031.98Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-11033.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 100. C @ 0. min, 10. K/min
CapillaryDB-11029.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 100. C @ 0. min, 5. K/min
CapillaryDB-11020.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 50. C @ 0. min, 10. K/min
CapillaryDB-11012.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 50. C @ 0. min, 5. K/min
PackedSE-301037.Buchman, Cao, et al., 1984He, Chromosorb AW, 40. C @ 10. min, 10. K/min, 210. C @ 30. min; Column length: 3.05 m

Van Den Dool and Kratz RI, polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-Wax1432.76Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 10. K/min; Tstart: 100. C
CapillaryDB-Wax1431.71Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 5. K/min; Tstart: 100. C
CapillaryDB-Wax1449.23Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 10. K/min; Tstart: 50. C
CapillaryDB-Wax1437.45Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 5. K/min; Tstart: 50. C
PackedCarbowax 20M1483.Buchman, Cao, et al., 1984He, Supelcoport, 40. C @ 10. min, 10. K/min, 210. C @ 30. min; Column length: 3.05 m

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1037.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP5-MS171.Vrana, Paschke, et al., 200530. m/0.25 mm/0.25 μm, Helium, 50. C @ 5. min, 5. K/min, 280. C @ 10. min

References

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Gerbino, Garbarino, et al., 1996
Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 1996, 86, 63-75. [all data]

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

Gerbino and Castello, 1995
Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 1995, 699, 1-2, 161-171, https://doi.org/10.1016/0021-9673(95)00024-H . [all data]

Buchman, Cao, et al., 1984
Buchman, O.; Cao, G.-Y.; Peng, C.T., Structure assignment by retention index in gas-liquid radiochromatography of substituted cyclohexenes, J. Chromatogr., 1984, 312, 75-90, https://doi.org/10.1016/S0021-9673(01)92765-7 . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]

Vrana, Paschke, et al., 2005
Vrana, B.; Paschke, H.; Paschke, A.; Popp, P.; Schuurmann, G., Performance of semipermeable membrane devices for sampling of organic contaminants in groun water, J. Envirom. Monit., 2005, 7, 5, 500-508, https://doi.org/10.1039/b411645c . [all data]


Notes

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References