Benzo[b]thiophene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Lee's RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5PB-1DB-5DB-5OV-73
Column length (m) 25.50.30.30.68.
Carrier gas HeH2H2  
Substrate      
Column diameter (mm) 0.30.320.320.250.28
Phase thickness (μm)  0.20.250.250.15
Tstart (C) 60.80.80.40. 
Tend (C) 270.270.270.280. 
Heat rate (K/min) 5.4.4.4.1.5
Initial hold (min) 2.2.2.2. 
Final hold (min)  5.5.5. 
I 201.57200.92201.34201.29201.6
ReferenceWilliams and Bottrill, 1995Andersson and Weis, 1994Andersson and Weis, 1994Wise, Benner, et al., 1988Arpino, Ignatiadis, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase DB-5SE-52SE-52SE-52
Column length (m) 30.20.20.12.
Carrier gas HeH2H2He
Substrate     
Column diameter (mm) 0.260.300.300.3
Phase thickness (μm) 0.250.250.250.34
Tstart (C) 50.40.40.50.
Tend (C) 300.265.265.250.
Heat rate (K/min) 6.4.4.2.
Initial hold (min) 4.2.2. 
Final hold (min) 20.   
I 201.84201.43201.57201.47
ReferenceRostad and Pereira, 1986Vassilaros, Kong, et al., 1982Vassilaros, Kong, et al., 1982Lee, Vassilaros, et al., 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Lee's RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Williams and Bottrill, 1995
Williams, P.T.; Bottrill, R.P., Sulfur-polycyclic aromatic hydrocarbons in tyre pyrolysis oil, Fuel, 1995, 74, 5, 736-742, https://doi.org/10.1016/0016-2361(94)00005-C . [all data]

Andersson and Weis, 1994
Andersson, J.T.; Weis, U., Gas Chromatographic Determination of Polycyclic Aromatic Compounds with Fluorinated Analogues as Internal Standards, J. Chromatogr. A, 1994, 659, 1, 151-161, https://doi.org/10.1016/0021-9673(94)85017-8 . [all data]

Wise, Benner, et al., 1988
Wise, S.A.; Benner, B.A.; Byrd, G.D.; Chesler, S.N.; Rebbert, R.E.; Schantz, M.M., Determination of polycyclic aromatic hydrocarbons in a coal tar standard reference material, Anal. Chem., 1988, 60, 9, 887-894, https://doi.org/10.1021/ac00160a012 . [all data]

Arpino, Ignatiadis, et al., 1987
Arpino, P.J.; Ignatiadis, I.; de Rycke, G., Sulphur-containing polynuclear aromatic hydrocarbons from petroleum. Examination of their possible statistical formation in sediments, J. Chromatogr., 1987, 390, 2, 329-348, https://doi.org/10.1016/S0021-9673(01)94385-7 . [all data]

Rostad and Pereira, 1986
Rostad, C.E.; Pereira, W.E., Kovats and Lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 6, 328-334, https://doi.org/10.1002/jhrc.1240090603 . [all data]

Vassilaros, Kong, et al., 1982
Vassilaros, D.L.; Kong, R.C.; Later, D.W.; Lee, M.L., Linear retention index system for polycyclic aromatic compounds. Critical evaluation and additional indices, J. Chromatogr., 1982, 252, 1-20, https://doi.org/10.1016/S0021-9673(01)88394-1 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]


Notes

Go To: Top, Lee's RI, non-polar column, temperature ramp, References