Benzo[b]thiophene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PONAPONAPB-1DB-5DB-1
Column length (m) 50.50.50.30.60.
Carrier gas N2 H2H2He
Substrate      
Column diameter (mm) 0.200.200.320.320.25
Phase thickness (μm) 0.500.500.20.251.0
Tstart (C) 35.30.80.80.40.
Tend (C) 170.150.270.270.260.
Heat rate (K/min) 2.2.4.4.2.
Initial hold (min)   2.2.5.
Final hold (min)   5.5.60.
I 1205.1165.1169.1172.1145.
ReferenceYang, Wang, et al., 2004Yang, Wang, et al., 2003Andersson and Weis, 1994Andersson and Weis, 1994Yu, Wu, et al., 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase Ultra-1
Column length (m) 25.
Carrier gas He
Substrate  
Column diameter (mm) 0.32
Phase thickness (μm) 0.25
Tstart (C) 80.
Tend (C) 260.
Heat rate (K/min) 3.
Initial hold (min)  
Final hold (min)  
I 1159.
ReferenceOkumura, 1991
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Yang, Wang, et al., 2004
Yang, Y.; Wang, Z.; Zong, B.; Yang, H., Determination of sulfur compounds in fluid catalytic cracking gasoline by gas chromatography with a sulfur chemiluminiscence detector, Chin. J. Chromatogr., 2004, 22, 3, 216-219. [all data]

Yang, Wang, et al., 2003
Yang, Y.-T.; Wang, Z.; Han. J.-H.; Tian, H.-P.; Yang, H.-Y., Determination of sulfur compounds in gasoline fraction of microreactor products by gas chromatography - Atomic emission detector, Petrochemical Technology (Shiyou Huagong), 2003, 32, 11, 995-998. [all data]

Andersson and Weis, 1994
Andersson, J.T.; Weis, U., Gas Chromatographic Determination of Polycyclic Aromatic Compounds with Fluorinated Analogues as Internal Standards, J. Chromatogr. A, 1994, 659, 1, 151-161, https://doi.org/10.1016/0021-9673(94)85017-8 . [all data]

Yu, Wu, et al., 1994
Yu, T.-H.; Wu, C.-M.; Ho, C.-T., Meat-like flavor generated from thermal interactions of glucose and alliin or deoxyalliin, J. Agric. Food Chem., 1994, 42, 4, 1005-1009, https://doi.org/10.1021/jf00040a032 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References