Adamantane, 1-chloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


IR Spectrum

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Gas Phase Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

IR spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Owner SRD/NIST
Collection (C) 2018 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin EPA-IR VAPOR PHASE LIBRARY
State gas

This IR spectrum is from the NIST/EPA Gas-Phase Infrared Database .


Gas Chromatography

Go To: Top, IR Spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedPMS-1000230.1316.Arutyunov, Kudryashov, et al., 2004N2, Chromaton N-AW-DMCS; Column length: 2. m
PackedSE-30150.1300.L'vova, Kurbatova, et al., 2001N2, N-AW Chromaton; Column length: 1. m
PackedApiezon L150.1350.L'vova, Kurbatova, et al., 2001N2, N-AW Chromaton; Column length: 1. m
PackedSE-30150.1300.Yashkin, Kurbatova, et al., 2001CHromaton N-AW; Column length: 1. m
CapillarySE-30145.1298.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm
CapillarySE-30160.1315.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm
CapillarySE-30175.1331.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm
CapillarySE-30190.1341.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedCarbowax 20M150.1691.L'vova, Kurbatova, et al., 2001N2, N-AW Chromaton; Column length: 1. m
PackedCarbowax 20M150.1691.Yashkin, Kurbatova, et al., 2001Column length: 1. m
CapillaryCarbowax 20M145.1689.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm
CapillaryCarbowax 20M160.1713.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm
CapillaryCarbowax 20M175.1741.Burkhard, Vais, et al., 1969N2; Column length: 50. m; Column diameter: 0.27 mm

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryAdamantyl siloxane160.1300.Konstantinova, Berezkin, et al., 200522. m/0.22 mm/0.20 μm, Nitrogen
CapillaryAdamantyl siloxane160.1300.Konstantinova, Berezkin, et al., 2005, 2Nitrogen; Column length: 22. m; Column diameter: 0.22 mm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryPolydimethyl siloxane1298.Bayat and Abad, 2011Program: not specified
CapillaryPolydimethyl siloxane1298.Bayat and Abad M.F.Y., 2011Program: not specified
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1286.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified

References

Go To: Top, IR Spectrum, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Arutyunov, Kudryashov, et al., 2004
Arutyunov, Y.I.; Kudryashov, S.Y.; Onuchak, L.A., Analysis of Mixtures Containing Unknown Components by Gas Chromatography: Determination of Molecular Mass, J. Anal. Chem. USSR (Engl. Transl.), 2004, 59, 4, 358-365. [all data]

L'vova, Kurbatova, et al., 2001
L'vova, N.Yu.; Kurbatova, S.V.; Yashkin, S.N.; Kolosova, E.A., Gas chromatography of halogenated adamantanes, Russ. J. Phys. Chem. (Engl. Transl.), 2001, 75, 12, 2053-2056. [all data]

Yashkin, Kurbatova, et al., 2001
Yashkin, S.N.; Kurbatova, S.V.; Buryak, A.K., Gas chromatography of halogenated adamantanes, Russ. Chem. Bull. (Engl. Transl.), 2001, 50, 5, 828-832, https://doi.org/10.1023/A:1011350908009 . [all data]

Burkhard, Vais, et al., 1969
Burkhard, J.; Vais, J.; Vodicka, L.; Landa, S., Adamantane and its derivatives. XVI. The gas chromatographic characterization of adamantane derivatives, J. Chromatogr., 1969, 42, 207-218, https://doi.org/10.1016/S0021-9673(01)80617-8 . [all data]

Konstantinova, Berezkin, et al., 2005
Konstantinova, K.K.; Berezkin, V.G.; Kurbatova, S.V.; Finkel'shtein, E.E., Relationship between physicochemical properties and chromatographic retention of some adamantane derivatives, Russ. J. Appl. Chem. (Engl. Transl.), 2005, 78, 9, 1498-1502, https://doi.org/10.1007/s11167-005-0546-y . [all data]

Konstantinova, Berezkin, et al., 2005, 2
Konstantinova, K.K.; Berezkin, V.G.; Kurbatova, S.V.; Finkel'stein, E.E., Relationship between Physicochemical Properties and Chromatographic Retention of Some Adamantane Derivatives, Rus. J. Applied Chem., 2005, 78, 9, 1522-1526, https://doi.org/10.1007/s11167-005-0546-y . [all data]

Bayat and Abad, 2011
Bayat, Z.; Abad, M.F.Y., Quantitative structure-property relationship (QSPR) study of Kovats retention indices of some of adamantane derivatives by the genetic algorithm amd nultiply linear regression (GA-MLR) method, Petroleum Coal, 2011, 53, 2, 132-140. [all data]

Bayat and Abad M.F.Y., 2011
Bayat, Z.; Abad M.F.Y., Computational approaches to the prediction of the Kovats retention index (RI) for adamantane derivatives (AD) as a drug, J. Chem. Pharm. Res., 2011, 3, 1, 48-55. [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]


Notes

Go To: Top, IR Spectrum, Gas Chromatography, References