Cyclopropane, butyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Quantity Value Units Method Reference Comment
Tboil371.15KN/ATurnbull and Wallis, 1956Uncertainty assigned by TRC = 1.5 K
Tboil372.7KN/AGragson, Greenlee, et al., 1955Uncertainty assigned by TRC = 0.6 K
Tboil372.7KN/AGragson, Greenlee, et al., 1955Uncertainty assigned by TRC = 0.5 K
Quantity Value Units Method Reference Comment
Tfus148.5KN/AGragson, Greenlee, et al., 1955Uncertainty assigned by TRC = 0.5 K
Tfus147.4KN/AGragson, Greenlee, et al., 1955Uncertainty assigned by TRC = 0.5 K

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Gas Chromatography

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSqualane60.712.Bogoslovsky, Anvaer, et al., 1978 
PackedSqualane80.714.Bogoslovsky, Anvaer, et al., 1978 
CapillarySqualane60.712.5Schomburg and Dielmann, 1973Column length: 100. m; Column diameter: 0.25 mm
CapillarySqualane80.713.7Schomburg and Dielmann, 1973Column length: 100. m; Column diameter: 0.25 mm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySqualane712.Chen, 2008Program: not specified

References

Go To: Top, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Turnbull and Wallis, 1956
Turnbull; Wallis, J. Org. Chem., 1956, 21, 663. [all data]

Gragson, Greenlee, et al., 1955
Gragson, J.T.; Greenlee, K.W.; Derfer, J.M.; Boord, C.E., Cyclopropane Hydrocarbons from γ-Bromo Ethers, J. Org. Chem., 1955, 20, 275. [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Schomburg and Dielmann, 1973
Schomburg, G.; Dielmann, G., Use of retention increments for identification and correlation of saturated and unsaturated cyclopropane hydrocarbons by means of Kovats indices, Anal. Chem., 1973, 45, 9, 1647-1658, https://doi.org/10.1021/ac60331a021 . [all data]

Chen, 2008
Chen, H.-F., Quantitative prediction of gas chromatography retention indices with support vector machines, radial basis neutral networks and multiple linear regression, Anal. Chim. Acta, 2008, 609, 1, 24-36, https://doi.org/10.1016/j.aca.2008.01.003 . [all data]


Notes

Go To: Top, Phase change data, Gas Chromatography, References