Fluoranthene, 3-nitro-
- Formula: C16H9NO2
- Molecular weight: 247.2482
- IUPAC Standard InChIKey: PIHGQKMEAMSUNA-UHFFFAOYSA-N
- CAS Registry Number: 892-21-7
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: 3-Nitrofluoranthene; 4-Nitrofluoranthene
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Ultra-1 | 2433. | Okumura, 1991 | 25. m/0.32 mm/0.25 μm, He, 3. K/min; Tstart: 80. C; Tend: 260. C |
Lee's RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | HP-5 | 412.45 | Pedersen, Durant, et al., 2005 | 30. m/0.25 mm/0.25 μm, Helium, 50. C @ 1.5 min, 6. K/min, 310. C @ 10. min |
Capillary | SE-52 | 413.34 | White, Robbat, et al., 1983 | 30. m/0.3 mm/0.25 μm, He, 4. K/min; Tstart: 25. C; Tend: 295. C |
Lee's RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5 | 411.89 | Ciccioli, Cecinato, et al., 1988 | Column diameter: 0.32 mm; Phase thickness: 1.0 μm; Program: 30 0C 20 0C/min -> 180 0C (3 min) 3 0C/min -> 270 0C |
Capillary | DB-5 | 413.24 | Ciccioli, Cecinato, et al., 1988 | Column diameter: 0.32 mm; Phase thickness: 1.0 μm; Program: not specified |
Capillary | DB-5 | 413.33 | Ciccioli, Cecinato, et al., 1988 | Column diameter: 0.32 mm; Phase thickness: 1.0 μm; Program: not specified |
Capillary | DB-5 | 413.34 | Ciccioli, Cecinato, et al., 1988 | Column diameter: 0.32 mm; Phase thickness: 1.0 μm; Program: not specified |
Capillary | OV-101 | 419.8 | Tucminen, Wickstrom, et al., 1986 | Program: not specified |
Capillary | OV-101 | 423.9 | Tucminen, Wickstrom, et al., 1986 | Program: not specified |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Okumura, 1991
Okumura, T.,
retention indices of environmental chemicals on methyl silicone capillary column,
Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333
. [all data]
Pedersen, Durant, et al., 2005
Pedersen, D.U.; Durant, J.L.; Taghizadeh, K.; Hemond, H.F.; Lafleur, A.L.; Cass, G.R.,
Human cell mutagenes in respirable airborne particles from the Northeastern United States. 2. Quantification of mutagenes and other organic compounds.,
Environ. Sci. Technol., 2005, 39, 24, 9547-9560, https://doi.org/10.1021/es050886c
. [all data]
White, Robbat, et al., 1983
White, C.M.; Robbat, A., Jr.; Hoes, R.M.,
Gas chromatographic retention characteristics of nitrated polycyclic aromatic hydrocarbons on SE-52,
Chromatographia, 1983, 17, 11, 605-612, https://doi.org/10.1007/BF02261944
. [all data]
Ciccioli, Cecinato, et al., 1988
Ciccioli, P.; Cecinato, A.; Brancaleoni, E.; Liberti, A.,
Short capillary column for the separation and identification of mononitrofluoranthene and mononitropyrene isomers present in air and emission samples,
J. Hi. Res. Chromatogr. Chromatogr. Comm., 1988, 11, 4, 306-312, https://doi.org/10.1002/jhrc.1240110402
. [all data]
Tucminen, Wickstrom, et al., 1986
Tucminen, A.; Wickstrom, K.; Pyysalo, H.,
Determination of Polycyclic Aromatic Compounds by GLC-Selected Ion Monitoring (SIM) Technique,
J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 8, 469-471, https://doi.org/10.1002/jhrc.1240090813
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.