Norflurane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Critical temperature

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director

Tc (K) Reference Comment
374.070Fujiwara, Nakamura, et al., 1998Uncertainty assigned by TRC = 0.04 K; 3 measurements made (two are the same) to check accuracy of technique, includes review of and comparison with previous literature, For ITS-90 scale; TRC
374.070Fujiwara, Nakamura, et al., 1998Uncertainty assigned by TRC = 0.02 K; 3 measurements made (two are the same) to check accuracy of technique, includes review of and comparison with previous literature, For ITS-90 scale; TRC
374.070Fujiwara, Nakamura, et al., 1998Uncertainty assigned by TRC = 0.02 K; 3 measurements made (two are the same) to check accuracy of technique, includes review of and comparison with previous literature, For ITS-90 scale; TRC
374.080Aoyama, Kishizawa, et al., 1996Uncertainty assigned by TRC = 0.02 K; For ITS-90 scale, at temp. corrs. to DC, includes review of and comparison with previous literature; TRC
373.80Economou, Peters, et al., 1995Uncertainty assigned by TRC = 0.5 K; TRC
374.11Higashi, 1995Uncertainty assigned by TRC = 0.05 K; TRC
374.11Higashi, 1994Uncertainty assigned by TRC = 0.03 K; TRC
374.250Morrison and Ward, 1991Uncertainty assigned by TRC = 0.05 K; TRC
374.18Fukushima, Watanabe, et al., 1990Uncertainty assigned by TRC = 0.1 K; TRC
374.2Fukushima, Watanabe, et al., 1990, 2Uncertainty assigned by TRC = 0.1 K; TRC
373.05Nishiumi and Yokoyama, 1990Uncertainty assigned by TRC = 0.3 K; TRC; Data excluded from overall average
374.25Basu and Wilson, 1989Uncertainty assigned by TRC = 0.15 K; TRC
374.3Kabata, Tanikawa, et al., 1989Uncertainty assigned by TRC = 0.01 K; TRC
374.27Yamashita, Kubota, et al., 1989Uncertainty assigned by TRC = 0.1 K; TRC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


References

Go To: Top, Critical temperature, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Fujiwara, Nakamura, et al., 1998
Fujiwara, K.; Nakamura, S.; Noguchi, M., Critical Parameters and Vapor Pressure Measurements for 1,1,1-Trifluoroethane (R-143a), J. Chem. Eng. Data, 1998, 43, 55-9. [all data]

Aoyama, Kishizawa, et al., 1996
Aoyama, H.; Kishizawa, G.; Sato, H.; Watanabe, K., Vapor-Liquid Coexistence Curves in the Critical Region and the Critical Temperatures and Densities of 1,1,1,2-Tetrafluoroethane (R-134a), 1,1,1- Trifluoroethane (R-143a), and 1,1,1,2,3,3- Hexafluorop, J. Chem. Eng. Data, 1996, 41, 1046-1051. [all data]

Economou, Peters, et al., 1995
Economou, I.G.; Peters, C.J.; Florusse, L.J.; De Swaan Arons, J., Phase behavior of the binary refrigerant mixture chlorodifluoro-ethane (R22 )-1,1,1,2-tetrafluoro-ethane (R134a): experimental investigation and theoretical modeling using the perturbed-anisotropic-c, Fluid Phase Equilib., 1995, 111, 239-52. [all data]

Higashi, 1995
Higashi, Y., Vapor-liquid equilibrium, coexistence curve, and critical locus for binary HFC-32/HFC-134a mixture, Int. J. Thermophys., 1995, 16, 1175-84. [all data]

Higashi, 1994
Higashi, Y., Critical parameters for HFC134a, HFC32 and HFC125, Int. J. Refrig., 1994, 17, 524-531. [all data]

Morrison and Ward, 1991
Morrison, G.; Ward, D., Thermodynamic properties of two alternative refrigerants: 1,1-dichloro-2,2, 2-trifluoroethane (R123) and 1,1,1,2- tetrafluoroethane (R134a), Fluid Phase Equilib., 1991, 62, 65-86. [all data]

Fukushima, Watanabe, et al., 1990
Fukushima, M.; Watanabe, N.; Kamimura, T., Measurements of the vapor-liquid coexistence curves and the critical parameters of HCFC123 and HFC134a, Nippon Reito Kyokai Ronbunshu, 1990, 7, 189-99. [all data]

Fukushima, Watanabe, et al., 1990, 2
Fukushima, M.; Watanabe, N.; Kamimura, T., Measurements of the PVT properties of HCFC123 and HFC134a, Nippon Reito Kyokai Ronbunshu, 1990, 7, 243-56. [all data]

Nishiumi and Yokoyama, 1990
Nishiumi, H.; Yokoyama, T., Vapor-Liquid equilibrium for the system of R134a-R22 in Proc. Symp. Thermophys. Prop., 11th, Tokyo, Japan, p 95, 1990. [all data]

Basu and Wilson, 1989
Basu, R.S.; Wilson, D.P., Thermophysical properties of 1,1,1,2-Tetrafluoroethane (R-134a), Int. J. Thermophys., 1989, 10, 591-603. [all data]

Kabata, Tanikawa, et al., 1989
Kabata, Y.; Tanikawa, S.; Uematsu, M.; Watanabe, K., Measurements of the vapor-liquid coexistence curve and the critical parameters for 1,1,1,2-Tetrafluoroethane, Int. J. Thermophys., 1989, 10, 605. [all data]

Yamashita, Kubota, et al., 1989
Yamashita, T.; Kubota, H.; Tanaka, Y.; Makita, T.; Kashiwagi, H., Physical properties of new halogenated hydrocarbons, Proc. Symp. Thermophys. Prop. 10th, 1989,, 1989, p 75-8. [all data]


Notes

Go To: Top, Critical temperature, References