Pentaerythritol Tetranitrate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Condensed phase thermochemistry data

Go To: Top, Phase change data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein

Quantity Value Units Method Reference Comment
Δfsolid-538.5 ± 0.8kJ/molCcbOrnellas, Carpenter, et al., 1966Heat of combustion corrected for pressure
Quantity Value Units Method Reference Comment
Δcsolid-2572.4 ± 0.8kJ/molCcbOrnellas, Carpenter, et al., 1966Heat of combustion corrected for pressure
Δcsolid-2569.8 ± 2.5kJ/molCcbBurlot, 1939Reanalyzed by Cox and Pilcher, 1970, Original value = -2594.7 kJ/mol

Phase change data

Go To: Top, Condensed phase thermochemistry data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
AC - William E. Acree, Jr., James S. Chickos
ALS - Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein

Quantity Value Units Method Reference Comment
Δsub150.4 ± 1.3kJ/molMECundall, Frank Palmer, et al., 1978Based on data from 328. to 405. K.; AC
Δsub152. ± 2.kJ/molVEdwards, 1953ALS

Enthalpy of sublimation

ΔsubH (kJ/mol) Temperature (K) Method Reference Comment
156.9 ± 0.8369.TELau, Hildenbrand, et al., 2004Based on data from 356. to 382. K.; AC
151.9 ± 2.1370. to 411.N/AEdwards, 1953See also Jones, 1960 and Cox and Pilcher, 1970, 2.; AC

Gas Chromatography

Go To: Top, Condensed phase thermochemistry data, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryDB-5140.1805.54Hobbs and Conde, 199230. m/0.25 mm/0.25 μm
CapillaryDB-5140.1813.94Hobbs and Conde, 199230. m/0.25 mm/0.25 μm

Kovats' RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone1791.Staples, 2005Column diameter: 0.25 mm; Program: not specified

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51785.Staples, 2004He; Program: not specified
CapillaryDB-51791.Staples, 2004He; Program: not specified

References

Go To: Top, Condensed phase thermochemistry data, Phase change data, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ornellas, Carpenter, et al., 1966
Ornellas, D.L.; Carpenter, J.H.; Gunn, S.R., Detonation calorimeter and results obtained with pentaerythritol tetranitrate (PETN), Rev. Sci. Instrum., 1966, 37, 907-912. [all data]

Burlot, 1939
Burlot, E., Etude relative a la calorimetrie des explosifs, Mem. Poudres, 1939, 29, 226-260. [all data]

Cox and Pilcher, 1970
Cox, J.D.; Pilcher, G., Thermochemistry of Organic and Organometallic Compounds, Academic Press, New York, 1970, 1-636. [all data]

Cundall, Frank Palmer, et al., 1978
Cundall, Robert B.; Frank Palmer, T.; Wood, Colin E.C., Vapour pressure measurements on some organic high explosives, J. Chem. Soc., Faraday Trans. 1, 1978, 74, 0, 1339, https://doi.org/10.1039/f19787401339 . [all data]

Edwards, 1953
Edwards, G., The vapour pressure of cyclo-trimethylenetrinitramine (cyclonite) and pentaerythritoltetranitrate, Trans. Faraday Soc., 1953, 49, 152. [all data]

Lau, Hildenbrand, et al., 2004
Lau, Kai H.; Hildenbrand, Donald L.; Crouch-Baker, Steven; Sanjurjo, Angel, Sublimation Pressure and Vapor Molecular Weight of Pentaerythritol Tetranitrate, J. Chem. Eng. Data, 2004, 49, 3, 544-546, https://doi.org/10.1021/je0302203 . [all data]

Jones, 1960
Jones, A.H., Sublimation Pressure Data for Organic Compounds., J. Chem. Eng. Data, 1960, 5, 2, 196-200, https://doi.org/10.1021/je60006a019 . [all data]

Cox and Pilcher, 1970, 2
Cox, J.D.; Pilcher, G., Thermochemistry of Organic and Organometallic Compounds, Academic Press Inc., London, 1970, 643. [all data]

Hobbs and Conde, 1992
Hobbs, J.R.; Conde, E.P., Gas chromatographic retention indices of explosives and nitro-compounds in Advances in Analysis and Detection of Explosives: Proceedings of the 4th International Symposium on Analysis of Detection of Explosives, September 7-10, 1992, Jerusalem Israel, J. Yinon, ed(s)., Kluwer Academic Publishers, Netherlands, 1992, 153-164. [all data]

Staples, 2005
Staples, E.J., Ultrahigh-speed chromatography and virtual chemical sensors for detecting explosives and chemical warfare agents, IEEE Sens. J., 2005, 5, 4, 622-631, https://doi.org/10.1109/JSEN.2005.850990 . [all data]

Staples, 2004
Staples, E.J., Analysis of odors from explosives using an electronic nose, 2004, retrieved from http://www.estcal.com/TechPapers/OdorsofExplosives.doc. [all data]


Notes

Go To: Top, Condensed phase thermochemistry data, Phase change data, Gas Chromatography, References