Butalbital
- Formula: C11H16N2O3
- Molecular weight: 224.2563
- IUPAC Standard InChIKey: UZVHFVZFNXBMQJ-UHFFFAOYSA-N
- CAS Registry Number: 77-26-9
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: 2,4,6(1H,3H,5H)-Pyrimidinetrione, 5-(2-methylpropyl)-5-(2-propenyl)-; Barbituric acid, 5-allyl-5-isobutyl-; Alisobumal; Allylbarbital; Allylbarbitone; Allylisobutylbarbital; Allylisobutylbarbituric acid; Butalbarbital; Isobutylallylbarbituric acid; Isobutylallylbarturic acid; Itobarbital; Optalidon; Sandoptal; Tetrallobarbital; 5-Allyl-5-(2-methylpropyl)barbituric acid; 5-Allyl-5-isobutylbarbituric acid; Allylbarbituric acid; 5-Allyl-5-(2'-methyl-n-propyl) barbituric acid; Profundal; 5-Allyl-5-isobutyl-2,4,6(1H,3H,5H)-pyrimidinetrione; Axotal; Fiorinal; Axocet
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Options:
IR Spectrum
Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: Coblentz Society, Inc.
Condensed Phase Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Notice: Except where noted, spectra from this collection were measured on dispersive instruments, often in carefully selected solvents, and hence may differ in detail from measurements on FTIR instruments or in other chemical environments. More information on the manner in which spectra in this collection were collected can be found here.
Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.
Additional Data
View scan of original (hardcopy) spectrum.
View image of digitized spectrum (can be printed in landscape orientation).
View spectrum image in SVG format.
Download spectrum in JCAMP-DX format.
Owner | COBLENTZ SOC. Collection (C) 2018 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Source reference | COBLENTZ NO. 05057 |
Date | 1963/02/25 |
Name(s) | 5-allyl-5-isobutyl-2,4,6(1H,3H,5H)-pyrimidinetrione SANDOPTAL |
State | SOLID (0.6 mg / 200 mg KBr DISC) |
Instrument | PERKIN-ELMER 21 (GRATING) INTERFERENCE FRINGES AROUND 680-750 |
Instrument parameters | FILTER AT ABOUT 10 MICRONS |
Resolution | 2 |
Sampling procedure | TRANSMISSION |
Data processing | DIGITIZED BY COBLENTZ SOCIETY (BATCH I) FROM HARD COPY |
Melting point | 138-139 C |
Mass spectrum (electron ionization)
Go To: Top, IR Spectrum, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | Virginia Division of Forensic Science |
NIST MS number | 250568 |
Gas Chromatography
Go To: Top, IR Spectrum, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | DB-5 | 220. | 1684. | Phillips, Logan, et al., 1990 | 15. m/0.25 mm/0.2 μm, He |
Capillary | SPB-1 | 250. | 1694. | Lora-Tamayo, Rams, et al., 1986 | He; Column length: 25. m; Column diameter: 0.20 mm |
Packed | SE-30 | 200. | 1658. | Stead, Gill, et al., 1982 |
Kovats' RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Packed | SE-30 | 1690. | Maurer, 1990 | N2, 100. C @ 3. min, 30. K/min, 310. C @ 5. min |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | VF-5MS | 1704.5 | Tretyakov, 2014 | 30. m/0.25 mm/0.25 μm, He; Tstart: 60. C; Tend: 270. C |
Capillary | SPB-1 | 1674. | Christ, Noomano, et al., 1988 | 30. m/0.75 mm/1.0 μm, He, 10. K/min, 280. C @ 12. min; Tstart: 160. C |
Capillary | CBP-1 | 1634. | Oyama, Sano, et al., 1987 | N2, 6. K/min; Column length: 12. m; Column diameter: 0.53 mm; Tstart: 120. C; Tend: 250. C |
Capillary | Methyl Silicone | 1637.0 | Newton and Foery, 1984 | 12. m/0.2 mm/0.33 μm, He, 50. C @ 1. min, 20. K/min, 300. C @ 3. min |
Capillary | 5 % Phenyl methyl siloxane | 1684.0 | Newton and Foery, 1984 | 12. m/0.2 mm/0.33 μm, He, 50. C @ 1. min, 20. K/min, 300. C @ 3. min |
Packed | SE-30 | 1670. | Perrigo and Peel, 1981 | N2, Chromosorb W, 130. C @ 2. min, 8. K/min, 290. C @ 8. min; Column length: 1.8 m |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | VF-5MS | 1706.1 | Tret'yakov, 2008 | 30. m/0.25 mm/0.25 μm, He; Program: Multi-step temperature program; T(initial)=60C; T(final)=270C |
Normal alkane RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | BP-1 | 1642. | MHA, 9999 | Tstart: 100. C; Tend: 300. C |
Capillary | DB-1 | 1632. | Anderson and Fuller, 1987 | 10. m/0.53 mm/2.65 μm, He, 5. K/min; Tstart: 130. C; Tend: 230. C |
Capillary | DB-1 | 1643. | Sharp, 1987 | 15. m/0.25 mm/0.25 μm, He, 130. C @ 1. min, 10. K/min, 290. C @ 10. min |
Packed | OV-1 | 1685. | Marozzi, Gambaro, et al., 1982 | Gas Chrom P, 2.5 K/min; Column length: 2. m; Tstart: 120. C; Tend: 200. C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Other | Methyl Silicone | 1668. | Ardrey and Moffat, 1981 | Program: not specified |
References
Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Phillips, Logan, et al., 1990
Phillips, A.M.; Logan, B.K.; Stafford, D.T.,
Further applications for capillary gas chromatography in routine quantitative toxicological analyses,
J. Hi. Res. Chromatogr., 1990, 13, 11, 754-758, https://doi.org/10.1002/jhrc.1240131106
. [all data]
Lora-Tamayo, Rams, et al., 1986
Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R.,
Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns,
J. Chromatogr., 1986, 374, 73-85, https://doi.org/10.1016/S0378-4347(00)83254-5
. [all data]
Stead, Gill, et al., 1982
Stead, A.H.; Gill, R.; Evans, A.T.; Moffat, A.C.,
Predictions of gas chromatographic retention characteristics of barbiturates from molecular structure,
J. Chromatogr., 1982, 234, 2, 277-283, https://doi.org/10.1016/S0021-9673(00)81866-X
. [all data]
Maurer, 1990
Maurer, H.H.,
Identification and differentiation of barbiturates, other sedative-hypnotics and their metabolites in urine integrated in a general screening procedure using computerized gas chromatography-mass spectrometry,
J. Chromatogr., 1990, 530, 307-326, https://doi.org/10.1016/S0378-4347(00)82334-8
. [all data]
Tretyakov, 2014
Tretyakov, K.V.,
Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2014. [all data]
Christ, Noomano, et al., 1988
Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D.,
Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection,
J. Anal. Toxicol., 1988, 12, 2, 84-88, https://doi.org/10.1093/jat/12.2.84
. [all data]
Oyama, Sano, et al., 1987
Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K.,
Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices,
Eisei Kagaku, 1987, 33, 5, 342-348, https://doi.org/10.1248/jhs1956.33.342
. [all data]
Newton and Foery, 1984
Newton, B.; Foery, R.F.,
Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology,
J. Anal. Toxicol., 1984, 8, 3, 129-134, https://doi.org/10.1093/jat/8.3.129
. [all data]
Perrigo and Peel, 1981
Perrigo, B.J.; Peel, H.W.,
The use of retention indices and temperature-programmed gas chromatography in analytical toxicology,
J. Chromatogr. Sci., 1981, 19, 5, 219-226, https://doi.org/10.1093/chromsci/19.5.219
. [all data]
Tret'yakov, 2008
Tret'yakov, K.V.,
Retention Data. NIST Mass Spectrometry Data Center., NIST Mass Spectrometry Data Center, 2008. [all data]
MHA, 9999
MHA, Directorate of ForensicScience.,
Forensic Toxicology, 9999. [all data]
Anderson and Fuller, 1987
Anderson, W.H.; Fuller, D.C.,
A simplified procedure for the isolation, characterization, and identification of weak acid and neutral drugs from whole blood,
J. Anal. Toxicol., 1987, 11, 5, 198-204, https://doi.org/10.1093/jat/11.5.198
. [all data]
Sharp, 1987
Sharp, M.E.,
A rapid screening procedure for acidic and neutral drugs in blood by high resolution gas chromatography,
J. Anal. Toxicol., 1987, 11, 1, 8-11, https://doi.org/10.1093/jat/11.1.8
. [all data]
Marozzi, Gambaro, et al., 1982
Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F.,
Use of the retention index in gas chromatographic studies of drugs,
J. Anal. Toxicol., 1982, 6, 4, 185-192, https://doi.org/10.1093/jat/6.4.185
. [all data]
Ardrey and Moffat, 1981
Ardrey, R.E.; Moffat, A.C.,
Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase,
J. Chromatogr., 1981, 220, 3, 195-252, https://doi.org/10.1016/S0021-9673(00)81925-1
. [all data]
Notes
Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.