Heptachlor

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1OV-1OV-1OV-1OV-1
Column length (m) 25.25.25.25.25.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm) 0.100.100.100.100.10
Tstart (C) 160.160.160.160.160.
Tend (C) 240.240.240.240.240.
Heat rate (K/min) 1.1.1.31.31.5
Initial hold (min) 1.1.1.1.1.
Final hold (min)      
I 1861.1863.1865.1867.1861.
Referencede Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPacked
Active phase OV-1OV-1OV-1SE-30
Column length (m) 25.25.25.1.8
Carrier gas    N2
Substrate    Chromosorb W
Column diameter (mm) 0.320.320.32 
Phase thickness (μm) 0.100.100.10 
Tstart (C) 160.160.160.130.
Tend (C) 240.240.240.290.
Heat rate (K/min) 1.52.2.8.
Initial hold (min) 1.1.1.2.
Final hold (min)    8.
I 1863.1866.1867.1870.
Referencede Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991Perrigo and Peel, 1981
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

de Paoli, Taccheo-Barbina, et al., 1991
de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 1991, 547, 355-365, https://doi.org/10.1016/S0021-9673(01)88659-3 . [all data]

Perrigo and Peel, 1981
Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 1981, 19, 5, 219-226, https://doi.org/10.1093/chromsci/19.5.219 . [all data]