NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedC78, Branched paraffin130.428.1Dallos, Sisak, et al., 2000He; Column length: 3.3 m
PackedC78, Branched paraffin130.428.0Reddy, Dutoit, et al., 1992Chromosorb G HP; Column length: 3.3 m
PackedApolane110.428.4Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane130.427.6Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane150.426.8Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane170.425.9Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane190.424.8Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane210.423.6Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane230.422.4Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane30.430.Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane50.429.8Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane70.429.4Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane90.429.Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
PackedApolane70.429.4Riedo, Fritz, et al., 1976He, Chromosorb; Column length: 2.4 m
CapillaryApiezon L160.420.Peetre and Smith, 1974 

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedApieson M160.420.Ellren, Peetre, et al., 1974Chromosorb G AW DMCS (80-100 mesh)

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillarySqualane419.Szekely, Nefedov, et al., 1967Nitrogen, 5. K/min; Column length: 50. m; Column diameter: 0.25 mm; Tstart: 60. C; Tend: 250. C

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Dallos, Sisak, et al., 2000
Dallos, A.; Sisak, A.; Kulcsár, Z.; Kováts, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 2000, 904, 2, 211-242, https://doi.org/10.1016/S0021-9673(00)00908-0 . [all data]

Reddy, Dutoit, et al., 1992
Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 1992, 609, 1-2, 229-259, https://doi.org/10.1016/0021-9673(92)80167-S . [all data]

Riedo, Fritz, et al., 1976
Riedo, F.; Fritz, D.; Tarján, G.; Kováts, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 1976, 126, 63-83, https://doi.org/10.1016/S0021-9673(01)84063-2 . [all data]

Peetre and Smith, 1974
Peetre, I.-B.; Smith, B.E.F., Gas chromatographic investigation of organometallic compounds and their carbon analogues. IV. determination, calculation and correlation of Kováts retention indices for tetraalkylsilanes, J. Chromatogr., 1974, 90, 1, 41-55, https://doi.org/10.1016/S0021-9673(01)94772-7 . [all data]

Ellren, Peetre, et al., 1974
Ellren, O.; Peetre, I.B.; Smith, B.E.F., Gas chromatographic investigation of organometallic compounds and their carbon analogues. V. Use of refractive index in conjunction with Kovats retention index for the identification of organosilicon compounds, J. Chromatogr., 1974, 93, 2, 383-392, https://doi.org/10.1016/S0021-9673(01)85402-9 . [all data]

Szekely, Nefedov, et al., 1967
Szekely, T.; Nefedov, O.M.; Garzo, G.; Shiryayav, V.I.; Fritz, D., Gas chromatographic investigation of the thermal decomposition of polydimethylsilylene, Acta Chim. Acad. Sci. Hung., 1967, 54, 3-4, 241-254. [all data]


Notes

Go To: Top, Gas Chromatography, References