Ethane, 1,1-dichloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1HP-1HP-1
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.25
Temperature (C) 0.10.20.30.40.
I 592.2593.3601.6598.9594.2
ReferenceWang, Liu, et al., 2005Wang, Liu, et al., 2005Wang, Liu, et al., 2005Wang, Liu, et al., 2005Wang, Liu, et al., 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase HP-1HP-1DB-1OV-1OV-1
Column length (m) 30.30.30.30.3.
Carrier gas   He He
Substrate     Chromosorb W DMCS
Column diameter (mm) 0.250.250.530.32 
Phase thickness (μm) 0.250.255.00.96 
Temperature (C) 50.60.60.50.100.
I 590.6585.9560.564.568.
ReferenceWang, Liu, et al., 2005Wang, Liu, et al., 2005Dewulf, Van Langenhove, et al., 1997Villalobos, 1995Castello and Gerbino, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase OV-1OV-1
Column length (m) 3.3.
Carrier gas HeHe
Substrate Chromosorb W DMCSChromosorb W DMCS
Column diameter (mm)   
Phase thickness (μm)   
Temperature (C) 125.75.
I 570.566.
ReferenceCastello and Gerbino, 1988Castello and Gerbino, 1988
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Wang, Liu, et al., 2005
Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 2005, 81, 2, 184-190, https://doi.org/10.1016/j.microc.2005.02.003 . [all data]

Dewulf, Van Langenhove, et al., 1997
Dewulf, J.; Van Langenhove, H.; Everaert, M., Solid-phase microextraction of volatile organic compounds estimation of the sorption equilibrium from the Kováts index, effect of salinity and humic acids and the study of the kinetics by the development of an agitated/static layer model, J. Chromatogr. A, 1997, 761, 1-2, 205-217, https://doi.org/10.1016/S0021-9673(96)00810-2 . [all data]

Villalobos, 1995
Villalobos, R., A window diagram for key component analysis in on-line gas chromatography, J. Hi. Res. Chromatogr., 1995, 18, 6, 343-347, https://doi.org/10.1002/jhrc.1240180604 . [all data]

Castello and Gerbino, 1988
Castello, G.; Gerbino, T.C., Effect of Temperature on the Gas Chromatographic Separation of Halogenated Compounds on Polar and Non-Polar Stationary Phases, J. Chromatogr., 1988, 437, 33-45, https://doi.org/10.1016/S0021-9673(00)90369-8 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References