Ethyl bromide

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedPackedPacked
Active phase OV-1OV-1OV-1SE-30Porapack Q
Column length (m) 3.3.3.2. 
Carrier gas HeHeHe N2
Substrate Chromosorb W DMCSChromosorb W DMCSChromosorb W DMCSGaschrom Q 
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 100.125.75.100.200.
I 524.529.517.522.484.
ReferenceCastello and Gerbino, 1988Castello and Gerbino, 1988Castello and Gerbino, 1988Winskowski, 1983Goebel, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase ApolaneDC-200SqualaneApiezon LApiezon L
Column length (m) 2.44.5.5. 
Carrier gas He    
Substrate Chromosorb   Celite (40:60 Gewichtsverhaltnis)
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 70.100.100.100.130.
I 509.6519.504.529.530.
ReferenceRiedo, Fritz, et al., 1976Rohrschneider, 1966Rohrschneider, 1966Rohrschneider, 1966von Kováts, 1958
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Apiezon L
Column length (m)  
Carrier gas  
Substrate Celite (40:60 Gewichtsverhaltnis)
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 70.
I 522.
Referencevon Kováts, 1958
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Castello and Gerbino, 1988
Castello, G.; Gerbino, T.C., Effect of Temperature on the Gas Chromatographic Separation of Halogenated Compounds on Polar and Non-Polar Stationary Phases, J. Chromatogr., 1988, 437, 33-45, https://doi.org/10.1016/S0021-9673(00)90369-8 . [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Goebel, 1982
Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 1982, 235, 1, 119-127, https://doi.org/10.1016/S0021-9673(00)95793-5 . [all data]

Riedo, Fritz, et al., 1976
Riedo, F.; Fritz, D.; Tarján, G.; Kováts, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 1976, 126, 63-83, https://doi.org/10.1016/S0021-9673(01)84063-2 . [all data]

Rohrschneider, 1966
Rohrschneider, L., Eine methode zur charakterisierung von gaschromatographischen trennflüssigkeiten, J. Chromatogr., 1966, 22, 6-22, https://doi.org/10.1016/S0021-9673(01)97064-5 . [all data]

von Kováts, 1958
von Kováts, E., 206. Gas-chromatographische Charakterisierung organischer Verbindungen. Teil 1: Retentionsindices aliphatischer Halogenide, Alkohole, Aldehyde und Ketone, Helv. Chim. Acta, 1958, 41, 7, 1915-1932, https://doi.org/10.1002/hlca.19580410703 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References