Tetramethyl silicate

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, IR Spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
AC - William E. Acree, Jr., James S. Chickos

Quantity Value Units Method Reference Comment
Tboil394. to 395.KN/APCR Inc., 1990BS
Quantity Value Units Method Reference Comment
Δvap9.9 ± 0.2kcal/molCVoronkov, Baryshok, et al., 1988AC
Δvap9.89 ± 0.05kcal/molEBKlyuchnikov, Danilova, et al., 1985AC

Enthalpy of vaporization

ΔvapH (kcal/mol) Temperature (K) Method Reference Comment
9.80324.N/AThomas, Smith, et al., 2007Based on data from 309. to 394. K.; AC
9.08379.EBKato and Tanaka, 1989Based on data from 364. to 393. K.; AC

IR Spectrum

Go To: Top, Phase change data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Coblentz Society, Inc.

Condensed Phase Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

IR spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Notice: Except where noted, spectra from this collection were measured on dispersive instruments, often in carefully selected solvents, and hence may differ in detail from measurements on FTIR instruments or in other chemical environments. More information on the manner in which spectra in this collection were collected can be found here.

Notice: Concentration information is not available for this spectrum and, therefore, molar absorptivity values cannot be derived.

Additional Data

View scan of original (hardcopy) spectrum.

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Owner COBLENTZ SOCIETY
Collection (C) 2018 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin DOW CORNING CORP.
Source reference COBLENTZ NO. 5589
Date 1965/09/07
Name(s) tetramethyl orthosilicate
State SOLUTION (10% IN CCl4 FOR 3800-1300, 2% IN CS2 FOR 1300-650, AND 10% IN CCl4 FOR 650-250 CM-1)
75% PURE BY GLC
Instrument PERKIN-ELMER 521 (GRATING)
Instrument parameters FILTERS AT 3150, 2500, 2000, 1150, 700, 410. GRATING CHANGES: 2000, 630 CM-1
Path length 0.011 CM, 0.012 CM, AND 0.020 CM
SPECTRAL FEATURE AT 635 CM-1 IS AFFECTED BY A CHANGE IN SOLVENT
Resolution 2
Sampling procedure TRANSMISSION
Data processing DIGITIZED BY NIST FROM HARD COPY (FROM TWO SEGMENTS)
Boiling point 123 C

This IR spectrum is from the Coblentz Society's evaluated infrared reference spectra collection.


Gas Chromatography

Go To: Top, Phase change data, IR Spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedApiezon L100.668.Kreshkov, Kirichenko, et al., 1975Ar; Column length: 1. m
CapillaryApiezon L160.668.2Peetre, 1974Column length: 50. m; Column diameter: 0.25 mm

References

Go To: Top, Phase change data, IR Spectrum, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

PCR Inc., 1990
PCR Inc., Research Chemicals Catalog 1990-1991, PCR Inc., Gainesville, FL, 1990, 1. [all data]

Voronkov, Baryshok, et al., 1988
Voronkov, M.G.; Baryshok, V.P.; Klyuchnikov, V.A.; Danilova, T.F.; Pepekin, V.I.; Korchagina, A.N.; Khudobin, Yu.I., Thermochemistry of organosilicon compounds, Journal of Organometallic Chemistry, 1988, 345, 1-2, 27-38, https://doi.org/10.1016/0022-328X(88)80231-6 . [all data]

Klyuchnikov, Danilova, et al., 1985
Klyuchnikov, V.A.; Danilova, T.F.; Voronkov, M.G.; D'yakov, V.M., Dokl. Phys. Chem., 1985, 281, 373. [all data]

Thomas, Smith, et al., 2007
Thomas, Leo H.; Smith, Harry; Davies, Gwyn H., Vapour pressures, molar entropies of vaporisation and liquid-state conformation of alkoxides, J. Chem. Technol. Biotechnol., 2007, 30, 1, 476-480, https://doi.org/10.1002/jctb.503300160 . [all data]

Kato and Tanaka, 1989
Kato, Masahiro; Tanaka, Hiroyuki, Ebulliometric measurement of vapor-liquid equilibria for four binary systems: methanol + silicon tetramethoxide, methanol + silicon tetraethoxide, ethanol + silicon tetramethoxide, and ethanol + silicon tetraethoxide, J. Chem. Eng. Data, 1989, 34, 2, 206-209, https://doi.org/10.1021/je00056a018 . [all data]

Kreshkov, Kirichenko, et al., 1975
Kreshkov, A.P.; Kirichenko, É.A.; Markov, B.A., Retention indices of alkoxychlorosilanes, Zh. Anal. Khim., 1975, 30, 2, 286-289. [all data]

Peetre, 1974
Peetre, I.-B., Gas chromatographic investigation of organometallic compounds and their carbon analogues. II. Improved method for calculating retention indices of tetraalkoxysilanes, J. Chromatogr., 1974, 88, 2, 311-321, https://doi.org/10.1016/S0021-9673(00)83155-6 . [all data]


Notes

Go To: Top, Phase change data, IR Spectrum, Gas Chromatography, References