D-Glucose, 5TMS derivative
- Formula: C21H52O6Si5
- Molecular weight: 541.0615
- IUPAC Standard InChIKey: PPTMWEDTYQRQBC-UHFFFAOYSA-N
- CAS Registry Number: 6736-97-6
- Chemical structure:
This structure is also available as a 2d Mol file - Species with the same structure:
- Stereoisomers:
- Other names: D-Glucose, 2,3,4,5,6-pentakis-O-(trimethylsilyl)-; D-Glucose, pentakis-O-(trimethylsilyl)-; Pentakis-O-(trimethylsilyl)-D-glucose; D-Glucose, penta-TMS; Glucose, TMS; Glucose, TMS, # 2; B-Glucose TMS; B-D-Glucose, TMS; A-D-Glucose, TMS; L-Glucose, TMS; A-Glucose TMS; D-Glucose, TMS; Glucose, TMS # 1
- Information on this page:
- Options:
Mass spectrum (electron ionization)
Go To: Top, Gas Chromatography, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Spectrum
Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.
Additional Data
View image of digitized spectrum (can be printed in landscape orientation).
Due to licensing restrictions, this spectrum cannot be downloaded.
Owner | NIST Mass Spectrometry Data Center Collection (C) 2014 copyright by the U.S. Secretary of Commerce on behalf of the United States of America. All rights reserved. |
---|---|
Origin | O A MAMER, MCGILL UNIVERSITY, MONTRE |
NIST MS number | 79231 |
Gas Chromatography
Go To: Top, Mass spectrum (electron ionization), References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-5 | 1926. | Fu, Iga, et al., 2000 | 30. m/0.25 mm/0.25 μm, He, 100. C @ 1. min, 10. K/min, 290. C @ 8. min |
Van Den Dool and Kratz RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | DB-1 | 1930. | Yang and Cashman, 1992 | 30. m/0.32 mm/1.0 μm, He; Program: 3 min at 100 0C; 100 - 200 0C at 8 deg/min; 1 min at 200 0C; 200 - 280 0C at 5 deg/min; 30 min at 280 0C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | OV-101 | 1937. | Binder and Haddon, 1984 | Helium; Column length: 42. m; Column diameter: 0.50 mm; Program: 60 0C (0.5 min) 30 0C/min -> 170 0C 3 0C/min -> 220 0C |
Capillary | OV-101 | 1934. | Binder and Haddon, 1984 | Helium; Column length: 42. m; Column diameter: 0.50 mm; Program: 80 0C (0.5 min) 30 0C/min -> 170 0C 3 0C/min -> 220 0C |
References
Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Fu, Iga, et al., 2000
Fu, X.; Iga, M.; Kimura, M.; Yamaguchi, S.,
Simplified screening for organic acidemia using GC/MS and dried urine filter paper: a study on neonatal mass screening,
Early Hum. Dev., 2000, 58, 1, 41-55, https://doi.org/10.1016/S0378-3782(00)00053-0
. [all data]
Yang and Cashman, 1992
Yang, Z.C.; Cashman, J.R.,
Structure-retention index relationships for derivatized monosaccharides on non-polar gas chromatography columns,
J. Chromatogr., 1992, 596, 1, 79-84, https://doi.org/10.1016/0021-9673(92)80205-9
. [all data]
Binder and Haddon, 1984
Binder, R.B.; Haddon, W.F.,
Analysis of O-methylinositols by gas-liquid chromatography-mass spectrometry,
Carbohydrate Research, 1984, 129, 21-32, https://doi.org/10.1016/0008-6215(84)85295-7
. [all data]
Notes
Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.