Anthracene, tetradecahydro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryOV-1150.1518.Zhang, Chen, et al., 199725. m/0.2 mm/0.33 μm, N2
CapillaryOV-1150.1500.Zhang, Chen, et al., 199725. m/0.2 mm/0.33 μm, N2
CapillaryOV-1160.1528.Zhang, Chen, et al., 199725. m/0.2 mm/0.33 μm, N2
CapillarySE-30150.1483.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30175.1508.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30130.1480.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30150.1500.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30175.1523.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30130.1498.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30150.1518.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30175.1544.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30130.1529.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30150.1550.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
CapillarySE-30130.1540.Bredael, 1982Column length: 100. m; Column diameter: 0.5 mm
PackedSE-30150.1481.Shlyakhov, Anvaer, et al., 1975 
PackedSE-30200.1520.Shlyakhov, Anvaer, et al., 1975 
PackedApiezon L150.1561.Shlyakhov, Anvaer, et al., 1975 

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zhang, Chen, et al., 1997
Zhang, M.; Chen, B.; Shen, S.; Chen, S., Compositional studies of high-temperature coal tar by g.c.-FT-i.r. analysis of middle oil fractions, Fuel, 1997, 76, 5, 415-423, https://doi.org/10.1016/S0016-2361(97)85518-4 . [all data]

Bredael, 1982
Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1982, 5, 6, 325-328, https://doi.org/10.1002/jhrc.1240050610 . [all data]

Shlyakhov, Anvaer, et al., 1975
Shlyakhov, A.F.; Anvaer, B.I.; Zolotareva, O.V.; Romina, N.N.; Novikova, N.V.; Koreshkova, R.I., On the possibility of group indentification of hydrocarbons by gas chromatography from temperature coefficients of retention indices, Zh. Anal. Khim., 1975, 30, 788-792. [all data]


Notes

Go To: Top, Gas Chromatography, References