cis-3-Hexenyl salicylate


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Japan AIST/NIMC Database- Spectrum MS-NW-5138
NIST MS number 232716

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-5MS1670.Pino, Mesa, et al., 200530. m/0.25 mm/0.25 μm, He, 60. C @ 2. min, 4. K/min, 250. C @ 20. min
CapillaryOV-1011637.7Wang and Sun, 198726. m/0.26 mm/0.3 μm, 2. K/min; Tstart: 100. C; Tend: 240. C
CapillaryOV-1011636.1Wang and Sun, 198726. m/0.26 mm/0.3 μm, 2. K/min; Tstart: 60. C; Tend: 240. C
CapillaryOV-1011651.8Wang and Sun, 198726. m/0.26 mm/0.3 μm, 8. K/min; Tstart: 60. C; Tend: 240. C
CapillaryOV-1011664.0Wang and Sun, 198721.5 m/0.27 mm/2. μm, 6. K/min; Tstart: 60. C; Tend: 240. C
CapillaryOV-1011640.8Wang and Sun, 198721.5 m/0.27 mm/0.14 μm, 6. K/min; Tstart: 60. C; Tend: 240. C
CapillaryOV-1011649.4Wang and Sun, 1987, 226.5 m/0.25 mm/0.14 μm, 70. C @ 4.08 min, 9. K/min; Tend: 240. C
CapillaryOV-1011654.55Wang, Zhong, et al., 198724. m/0.26 mm/0.5 μm, 6. K/min; Tstart: 80. C; Tend: 240. C

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-11643.7Yin and Sun, 199012. m/0.2 mm/0.33 μm, 40. C @ 0.395 min, 16. K/min
CapillaryHP-11629.1Yin and Sun, 199012. m/0.2 mm/0.33 μm, 40. C @ 0.4 min, 4. K/min
CapillaryHP-11644.3Yin and Sun, 199012. m/0.2 mm/0.33 μm, 40. C @ 0.801 min, 8. K/min
CapillaryHP-11643.7Yin and Sun, 199025. m/0.32 mm/0.52 μm, 40. C @ 0.8 min, 8. K/min
CapillaryHP-11647.8Yin and Sun, 199050. m/0.2 mm/0.11 μm, 40. C @ 3.194 min, 6. K/min

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySE-301654.Vinogradov, 2004Program: not specified

Normal alkane RI, polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillarySupelcowax 102274.Castioni and Kapetanidis, 199660. m/0.25 mm/0.25 μm, Helium; Program: 60 0C (10 min) 2 0C/min -> 80 0C 3 0C/min -> 100 0C 4 0C/min -> 220 0C (30 min)
CapillarySupelcowax 102285.Castioni and Kapetanidis, 199660. m/0.25 mm/0.25 μm, Helium; Program: not specified

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Pino, Mesa, et al., 2005
Pino, J.A.; Mesa, J.; Muñoz, Y.; Martí, M.P.; Marbot, R., Volatile components from mango (Mangifera indica L.) cultivars, J. Agric. Food Chem., 2005, 53, 6, 2213-2223, https://doi.org/10.1021/jf0402633 . [all data]

Wang and Sun, 1987
Wang, T.; Sun, Y., On the influence of the solute sample size on temperature-programmed retention indices, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1987, 10, 11, 603-606, https://doi.org/10.1002/jhrc.1240101105 . [all data]

Wang and Sun, 1987, 2
Wang, T.; Sun, Y., Reproducibility of Temperature-Programmed Retention Indices on Several OV-101 Columns, J. Chromatogr., 1987, 407, 79-86, https://doi.org/10.1016/S0021-9673(01)92606-8 . [all data]

Wang, Zhong, et al., 1987
Wang, T.; Zhong, B.; Chen, M.; Sun, Y., Definitions and Methods of Calculation of the Temperature-Programmed Retention Index, ITP. III. A Simplified Calculation Method Based on the Extended Kovats Definition, J. Chromatogr., 1987, 390, 2, 275-283, https://doi.org/10.1016/S0021-9673(01)94381-X . [all data]

Yin and Sun, 1990
Yin, H.F.; Sun, Y.L., The achievement of reproducible temperature programmed retention indices in gas chromatography when using different columns and detectors, Chromatographia, 1990, 29, 1/2, 39-43, https://doi.org/10.1007/BF02261137 . [all data]

Vinogradov, 2004
Vinogradov, B.A., Production, composition, properties and application of essential oils, 2004, retrieved from http://viness.narod.ru. [all data]

Castioni and Kapetanidis, 1996
Castioni, P.; Kapetanidis, I., Volatile constituents from Brunfelsia grandiflora ssp. grandiflora: qualitative analysis by GC-MS, Scientia Pharmaceutica, 1996, 64, 83-91. [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References