Hexane, 1-nitro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryHP-1100.1011.7Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-1110.1013.6Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-1120.1015.4Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-130.1001.2Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-140.1003.5Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-150.1004.4Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-160.1005.8Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-170.1006.6Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-180.1008.4Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryHP-190.1010.Görgényi and Héberger, 2003N2; Column length: 30. m; Phase thickness: 1.05 μm
CapillaryDB-1MS90.1009.7Vickers, Kuhn, et al., 200330. m/0.25 mm/0.25 μm, He
CapillaryDB-190.1009.4Vickers, Kuhn, et al., 200330. m/0.25 mm/0.25 μm, He
CapillaryDB-5140.1057.28Hobbs and Conde, 199230. m/0.25 mm/0.25 μm
PackedApolane130.970.Dutoit, 1991Column length: 3.7 m
PackedApiezon L100.992.Brown, Chapman, et al., 1968N2, DCMS-treated Chromosorb W; Column length: 2.3 m
PackedApiezon L150.1008.Brown, Chapman, et al., 1968N2, DCMS-treated Chromosorb W; Column length: 2.3 m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryHP-Innowax100.1527.3Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax110.1530.5Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax120.1533.4Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax50.1502.5Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax60.1506.9Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax70.1511.8Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax80.1516.8Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm
CapillaryHP-Innowax90.1521.6Görgényi and Héberger, 2003Column length: 30. m; Phase thickness: 0.5 μm

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-51050.Solina, Baumgartner, et al., 200525. m/0.2 mm/1. μm, He, 5. K/min, 280. C @ 5. min; Tstart: 40. C
CapillaryDB-51034.63Hobbs and Conde, 199230. m/0.25 mm/0.25 μm, 5. K/min; Tstart: 40. C; Tend: 300. C
CapillaryDB-51046.47Hobbs and Conde, 199230. m/0.25 mm/0.25 μm, 5. K/min; Tstart: 40. C; Tend: 300. C

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Görgényi and Héberger, 2003
Görgényi, M.; Héberger, K., Minimum in the temperature dependence of the Kováts retention indices of nitroalkanes and alkanenitriles on an apolar phase, J. Chromatogr. A, 2003, 985, 1-2, 11-19, https://doi.org/10.1016/S0021-9673(02)01842-3 . [all data]

Vickers, Kuhn, et al., 2003
Vickers, A.K.; Kuhn, E.; Lautamo, R., A novel, inert, low bleed column for GC-MS, 2003, retrieved from http://www.chem.agilent.com/cag/cabu/gcapps.htm. [all data]

Hobbs and Conde, 1992
Hobbs, J.R.; Conde, E.P., Gas chromatographic retention indices of explosives and nitro-compounds in Advances in Analysis and Detection of Explosives: Proceedings of the 4th International Symposium on Analysis of Detection of Explosives, September 7-10, 1992, Jerusalem Israel, J. Yinon, ed(s)., Kluwer Academic Publishers, Netherlands, 1992, 153-164. [all data]

Dutoit, 1991
Dutoit, J., Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases, J. Chromatogr., 1991, 555, 1-2, 191-204, https://doi.org/10.1016/S0021-9673(01)87179-X . [all data]

Brown, Chapman, et al., 1968
Brown, I.; Chapman, I.L.; Nicholson, G.J., Gas chromatography of polar solutes in electron acceptor stationary phases, Aust. J. Chem., 1968, 21, 5, 1125-1141, https://doi.org/10.1071/CH9681125 . [all data]

Solina, Baumgartner, et al., 2005
Solina, M.; Baumgartner, P.; Johnson, R.L.; Whitfield, F.B., Volatile aroma components of soy protein isolate and acid-hydrolysed vegetable protein, Food Chem., 2005, 90, 4, 861-873, https://doi.org/10.1016/j.foodchem.2004.06.005 . [all data]


Notes