Hexane, 1,1'-thiobis-
- Formula: C12H26S
- Molecular weight: 202.400
- IUPAC Standard InChIKey: LHNRHYOMDUJLLM-UHFFFAOYSA-N
- CAS Registry Number: 6294-31-1
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Hexyl sulfide; Di-n-hexyl sulfide; Dihexyl sulfide; 7-Thiatridecane; Normal-hexyl sulfide; n-Hexyl sulfide; dihexyl sulphide
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Packed | Apiezon M | 130. | 1473. | Garbuzov, Misharina, et al., 1985 | He or N2, Chromosorb W, AW-DMCS; Column length: 2.1 m |
Packed | SE-30 | 80. | 1468. | Zotov, Golovkin, et al., 1981 | N2, Chromaton N-AWHMDS; Column length: 1.8 m |
Packed | Apiezon M | 130. | 1473. | Golovnya and Misharina, 1980 | N2, Chromosorb W AW DMCS; Column length: 2.1 m |
Packed | Apiezon M | 130. | 1473. | Golovnya and Misharina, 1980, 2 | N2, Chromosorb W AW DMCS; Column length: 2.1 m |
Packed | SE-30 | 190. | 1499. | Golovkin, Smol'chenko, et al., 1980 | N2, Chromaton N-AW-DMCS; Column length: 1. m |
Packed | SE-30 | 110. | 1457. | Möckel and Zolg, 1977 | Chromosorb W AW (80-100 mesh); Column length: 2. m |
Packed | Apiezon M | 130. | 1473. | Golovnya, Garbuzov, et al., 1976 | N2, Chromosorb W; Column length: 2.1 m |
Packed | DC-200 | 120. | 1472. | Golovnya and Arsen'ev, 1970 | Column length: 1.5 m |
Packed | SE-30 | 130. | 1473. | Golovnya and Arsen'ev, 1970 | Column length: 1.5 m |
Kovats' RI, polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Packed | Carbowax 20M | 110. | 1667. | Möckel and Zolg, 1977 | He, Chromosorb W AW (80-100 mesh); Column length: 6. m |
Packed | Polyethylene Glycol | 130. | 1678. | Golovnya, Garbuzov, et al., 1976 | N2, Chromosorb W; Column length: 2.1 m |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Packed | SE-30 | 1473. | Zotov, Golovkin, et al., 1981 | N2, Chromaton N-AWHMDS, 3.9 K/min; Column length: 1.8 m; Tstart: 80. C; Tend: 250. C |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc. | 1473. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Garbuzov, Misharina, et al., 1985
Garbuzov, V.G.; Misharina, T.A.; Aerov, A.F.; Golovnya, R.V.,
Gas chromatographic retention indices for sulphur(II)-containing organic substances,
J. Anal. Chem. USSR (Engl. Transl.), 1985, 40, 4, 576-586. [all data]
Zotov, Golovkin, et al., 1981
Zotov, L.N.; Golovkin, G.V.; Golovnya, R.V.,
GC Behaviour of Symmetrical n-Dialkyl Sulphides under Isothermal and Temperature Programming Conditions,
J. Hi. Res. Chromatogr. Chromatogr. Comm., 1981, 4, 1, 6-10, https://doi.org/10.1002/jhrc.1240040103
. [all data]
Golovnya and Misharina, 1980
Golovnya, R.V.; Misharina, T.A.,
Determination of the energy of intermolecular interactions in gas chromatography from retention indices,
J. Chromatogr., 1980, 190, 1, 1-12, https://doi.org/10.1016/S0021-9673(00)85506-5
. [all data]
Golovnya and Misharina, 1980, 2
Golovnya, R.V.; Misharina, T.A.,
Gas-chromatographic determination of energy contributions of isoaliphatic and unsaturated groups in sulfides and disulfides and of sulfur atoms in metameric thiatridecanes from retention indices,
Izv. Akad. Nauk SSSR Ser. Khim., 1980, 12, 1937-1942. [all data]
Golovkin, Smol'chenko, et al., 1980
Golovkin, G.V.; Smol'chenko, A.I.; Zotov, L.N.; Sazonov, S.E.,
Systems of gas-chromatographic retention indices for identifying pesticides by means of selective detectors,
Zh. Anal. Khim., 1980, 35, 5, 651-655. [all data]
Möckel and Zolg, 1977
Möckel, H.J.; Zolg, M.,
Retentionsindices n-aliphatischer Schwefelverbindungen,
Z. Anal. Chem., 1977, 285, 1, 45-46, https://doi.org/10.1007/BF00446017
. [all data]
Golovnya, Garbuzov, et al., 1976
Golovnya, R.V.; Garbuzov, V.G.; Misharina, T.A.,
Gas chromatographic characteristics of sulfur compounds. 2. Normal sulfides,
Izv. Akad. Nauk Kaz. SSR Ser. Khim., 1976, 10, 2266-2270. [all data]
Golovnya and Arsen'ev, 1970
Golovnya, R.V.; Arsen'ev, Y.N.,
Gas-chromatographic method for the analysis of n-mercaptans and symmetrical n-sulfides and n-disulfides,
Bull. Acad. Sci. USSR, Div. Chem. Sci. (Engl. Transl.), 1970, 6, 4, 1316-1318, https://doi.org/10.1007/BF00852683
. [all data]
Waggott and Davies, 1984
Waggott, A.; Davies, I.W.,
Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.