Hexane, 1,1'-thiobis-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Mass spectrum (electron ionization)

Go To: Top, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin NIST Mass Spectrometry Data Center, 1994
NIST MS number 133255

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedApiezon M130.1473.Garbuzov, Misharina, et al., 1985He or N2, Chromosorb W, AW-DMCS; Column length: 2.1 m
PackedSE-3080.1468.Zotov, Golovkin, et al., 1981N2, Chromaton N-AWHMDS; Column length: 1.8 m
PackedApiezon M130.1473.Golovnya and Misharina, 1980N2, Chromosorb W AW DMCS; Column length: 2.1 m
PackedApiezon M130.1473.Golovnya and Misharina, 1980, 2N2, Chromosorb W AW DMCS; Column length: 2.1 m
PackedSE-30190.1499.Golovkin, Smol'chenko, et al., 1980N2, Chromaton N-AW-DMCS; Column length: 1. m
PackedSE-30110.1457.Möckel and Zolg, 1977Chromosorb W AW (80-100 mesh); Column length: 2. m
PackedApiezon M130.1473.Golovnya, Garbuzov, et al., 1976N2, Chromosorb W; Column length: 2.1 m
PackedDC-200120.1472.Golovnya and Arsen'ev, 1970Column length: 1.5 m
PackedSE-30130.1473.Golovnya and Arsen'ev, 1970Column length: 1.5 m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedCarbowax 20M110.1667.Möckel and Zolg, 1977He, Chromosorb W AW (80-100 mesh); Column length: 6. m
PackedPolyethylene Glycol130.1678.Golovnya, Garbuzov, et al., 1976N2, Chromosorb W; Column length: 2.1 m

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
PackedSE-301473.Zotov, Golovkin, et al., 1981N2, Chromaton N-AWHMDS, 3.9 K/min; Column length: 1.8 m; Tstart: 80. C; Tend: 250. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1473.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified

References

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Garbuzov, Misharina, et al., 1985
Garbuzov, V.G.; Misharina, T.A.; Aerov, A.F.; Golovnya, R.V., Gas chromatographic retention indices for sulphur(II)-containing organic substances, J. Anal. Chem. USSR (Engl. Transl.), 1985, 40, 4, 576-586. [all data]

Zotov, Golovkin, et al., 1981
Zotov, L.N.; Golovkin, G.V.; Golovnya, R.V., GC Behaviour of Symmetrical n-Dialkyl Sulphides under Isothermal and Temperature Programming Conditions, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1981, 4, 1, 6-10, https://doi.org/10.1002/jhrc.1240040103 . [all data]

Golovnya and Misharina, 1980
Golovnya, R.V.; Misharina, T.A., Determination of the energy of intermolecular interactions in gas chromatography from retention indices, J. Chromatogr., 1980, 190, 1, 1-12, https://doi.org/10.1016/S0021-9673(00)85506-5 . [all data]

Golovnya and Misharina, 1980, 2
Golovnya, R.V.; Misharina, T.A., Gas-chromatographic determination of energy contributions of isoaliphatic and unsaturated groups in sulfides and disulfides and of sulfur atoms in metameric thiatridecanes from retention indices, Izv. Akad. Nauk SSSR Ser. Khim., 1980, 12, 1937-1942. [all data]

Golovkin, Smol'chenko, et al., 1980
Golovkin, G.V.; Smol'chenko, A.I.; Zotov, L.N.; Sazonov, S.E., Systems of gas-chromatographic retention indices for identifying pesticides by means of selective detectors, Zh. Anal. Khim., 1980, 35, 5, 651-655. [all data]

Möckel and Zolg, 1977
Möckel, H.J.; Zolg, M., Retentionsindices n-aliphatischer Schwefelverbindungen, Z. Anal. Chem., 1977, 285, 1, 45-46, https://doi.org/10.1007/BF00446017 . [all data]

Golovnya, Garbuzov, et al., 1976
Golovnya, R.V.; Garbuzov, V.G.; Misharina, T.A., Gas chromatographic characteristics of sulfur compounds. 2. Normal sulfides, Izv. Akad. Nauk Kaz. SSR Ser. Khim., 1976, 10, 2266-2270. [all data]

Golovnya and Arsen'ev, 1970
Golovnya, R.V.; Arsen'ev, Y.N., Gas-chromatographic method for the analysis of n-mercaptans and symmetrical n-sulfides and n-disulfides, Bull. Acad. Sci. USSR, Div. Chem. Sci. (Engl. Transl.), 1970, 6, 4, 1316-1318, https://doi.org/10.1007/BF00852683 . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]


Notes

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References